Tabla de contenido
1.0

CONTROL PANEL

KEY 1 (red LED)
NORMAL FUNCTIONING:
- When pressed for five sec. it resets the HACCP (HA or HF) alarm if active.
LED:
- fixed light: HACCP alarm for exceeding time and threshold ( HA alarm).
- continuous flashing: HACCP alarm for exceeding time and threshold after lack of power supply ( HF alarm).
KEY 2 (LED yellow)
NORMAL FUNCTIONING:
- When pressed for 1 second it activates/deactivates the relay aux 1 outlet light.
LED:
- fixed light: Light switched on (outlet relay aux 1 active).
KEY 3 (LED green)
NORMAL FUNCTIONING:
- When pressed for 5 seconds ON/OFF unit.
LED:
- fixed light: Adjustment in function.
N.B.: The ON/OFF function depends on a parameter for enabling (if not enabled,
the control is always ON), the LED however indicated the status.
KEY 4 (LED orange)
NORMAL FUNCTIONING:
- When pressed increases/decreases the heating power of the de-misting system for external windows.
LED:
- fixed light: De-misting system working on full power.
- switched off: De-misting system working on half power.
KEY 5 (LED green)
NORMAL FUNCTIONING:
- When pressed for 5 seconds it activates the continuous cycle (after pressure of 5 seconds).
LED:
- fixed light: Continuous cycle inserted.
KEY 6 (LED green)
NORMAL FUNCTIONING:
- ON/OFF light after 1 second of pressure.
-When pressed together with key 7 for5 seconds it activates the continuous cycle.
PARAMETER MODIFICATION:
- c.
- Increases the value associated to the displayed parameter.
LED:
- switched on: Compressor functioning.
- continuous flashing: Request for Compressor activation (cold request).
KEY 7 (LED yellow)
NORMAL FUNCTIONING:
- When pressed for 5 seconds it activates manual defrosting (if conditions are present).
PARAMETER MODIFICATION:
- Pass from a parameter to the previous one.
- Decreases the value associated to the displayed parameter.
LED:
- fixed light: Defrosting functioning.
- continuous flashing: Defrosting pendent.
KEY 8 (LED red)
NORMAL FUNCTIONING:
- Switching off of acoustic alarm (if active).
- When pressed for 1 second it displays and/or sets the set-point.
- When pressed for more than 5 seconds, not in the presence of alarms, gives access to the parameters of type F (fre-
quent).
PARAMETER MODIFICATION:
- Displays the value of the selected value/exits from the display.
- When pressed for 5 seconds it memorises the modifications permanently.
LED:
- fixed light: Alarm active .
GelatoShow
GB
4 280 36392 2 ac
• 3
Tabla de contenido
loading