Wolf 800.222.7820 Guia De Instalacion página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

IN S TA L L AT I O N
Installation
For 60"
wide hoods only, remove and discard three
(1524)
2
shipping screws from the back of the hood. Refer to the
illustration below.
Remove the hood's internal frame indicated by the
3
shaded area. Remove only the four screws indicated in
the illustration below.
Remove one of the two electrical knockouts from the
4
back of the hood.
Remove the wood mounting strip from the back of the
5
hood by extracting the screws from inside the hood.
Remove the electrical cover from inside the hood. Refer
6
to the illustration below.
SHIPPING SCREWS
Screws (60" wide hoods only)
ELECTRICAL
COVER
Electrical cover
INTERNAL
FRAME
SCREWS
Internal frame
Remove the transition, hold-down brackets, and screws
7
from the packaging and use the hold-down brackets and
screws to secure the transition to the top of the hood.
Refer to the illustration below.
Position the mounting strip on the wall and secure it to
8
the wall framing with the wood screws provided. Refer to
the illustration below.
Lift the hood into position and insert Romex
9
the electrical box knockout and secure with the provided
connector.
Secure the hood to the mounting strip and wall structure
10
with the provided screws and washers.
Connect the ducting to the transition and secure with
11
duct sealing tape.
Reinstall the internal frame.
12
HOLD-DOWN
BRACKET
TRANSITION
Transition mounting
®
wire(s) into
MOUNTING STRIP
16"
(406)
Hood installation
wolfappliance.com | 7
Tabla de contenido
loading