Outer Clip
Adjust the Hot Temperature Limit
Remove the outer clip from the head nut.
Remove the detent collar.
Remove the spline adapter.
NOTE: Keep the detent collar off while making adjustments.
Turn the valve stem fully counterclockwise.
Using the volume control valve (not shown), turn on the water.
Allow the water to flow for several minutes until the water
temperature stabilizes.
Kohler Co.
Nut
Valve Stem
Spline Adapter
Detent Collar
9
1145568-5-A