Service the Stops
NOTE: Keep a rag handy to catch excess water that will gradually
drain when the stop cartridge is removed.
NOTE: Lubricate the seals of new assemblies with silicone.
Turn off both the hot and cold water at the nearest supply
shut-off or water main.
Verify that the water is off before continuing.
Loosen the screw and slide the locking bar up until it is clear of
the stops. Tighten the screw to keep the locking bar from sliding
back down.
Use a socket wrench to remove the stop assemblies.
Apply silicone lubricant to the rubber seals on the new
assemblies.
Thread the new stop assemblies into the valve. Do not
overtighten.
Open the stops using a socket wrench.
Loosen the screw on the locking bar and slide it down.
Tighten the screw.
Turn on the hot and cold water supplies.
Check for leaks.
Kohler Co.
Locking Bar
13
Seals
1145568-5-A