Tone at call beginning
When iP Access receives an incoming call and it auto-answers, it issues three short beeps
to indicate a call has begun. This feature can disable for certain remote silent monitoring
applications.
NOTE: Verify that the law of your country doesn't consider this feature as privacy violation.
At the bottom, you can see two buttons that only are in the main menu:
• REBOOT:
Restart the product (address of iP Access must be reloaded manually in the
browser). Follow this procedure to allow the product reload IP address, if it was
modified. Except for IP address, the rest of the parameters, are immediately
changed on the product when it is programmed
• RESTORE:
Reload all factory default settings (except the IP address)
Keys and buttons programming
In submenu:
program.
Digits qty for access control user
Access control user, according users quantity of the system:
• 1: 9 users: 1 to 9 (0: administrator)
• 2: 99 users 01 to 99 (00: administrator)
• 3: 999 users 01 to 999 (000: administrator)
Maximum number of dialed digits
iP Access can originate a call in three different ways:
• Dial to an extension number (if it is connected to an IP PBX)
• Call directly to an IP address, or
• Call to an extension number dialed by user (like a common telephone)
In the last case, the iP Access ends the dialing by time (4 seconds) or when the maximum
number of dialed digits is reached (which corresponds to the extensions numbering plan of
the IP PBX).
Action of key X or button X
The iP Access can be equipped with:
• Telephone keypad
• Simple buttons (1 or 2)
• Telephone keypad and simple buttons
The telephone keypad has the keys , 0 to 9, * (asterisk) and # (pound)