1/2", 5/8" and 3/4" Infalok
03200 and 73412-03300 for Avdel
Servicing Instructions
Nose assemblies should be serviced at weekly intervals. You should hold some stock of all internal components of the
nose assembly as they will need regular replacement.
Remove the nose assembly using the reverse procedure to the 'Fitting Instructions'.
Any worn or damaged part should be replaced.
Clean and check wear on Jaw Set 5.
Check that the collar Ejector 2, Follower 6, Sleeve 8 and 'O' Rings 7 are not distorted.
To remove a damaged or worn collar Ejector 2 cut at a point between the flange of the ejector and the end of Collet
3. The collar Ejector 2 and jaw Release 4 can then be separated and removed from Collet 3.
When assembling a new collar Ejector 2 and jaw Release 4 in the Collet 3, first ensure that the threads are clean,
before applying Loctite
Assemble according to the 'Fitting Instructions'.
12
®
Nose Assemblies - 73412-03100, 73412-
®
243 and screwing the two parts together within Collet 3.
®