Logic
Definition
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
*IBL TCA
Block pulses during
IBL CLOSE
closing
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
safety input SAFE 3.
SAFE 3
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
command input IC 3.
IC 3
Configuration of
command input IC 4.
IC 4
Configuration of
AUX 3 output.
AUX 3
26-37
22 -
SIRIO CBA 230 INV
INSTALLATION MANUAL
Cross out
Default
setting
used
1
 
0
 
0
 
TCA
0
 
0
 
0
72
6
74
2
77
0
61
4
62
 
2
64
3
65
0
 
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
1
WARNING: safety devices are not enabled.
CE certification has been awarded based on said configuration. BFT disclaims all responsibility
for the machine's use in any configuration other than the default configuration.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
2
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Standard operating mode (Fig.G Rif. 1).
1
Opens in other direction to standard operating mode (Fig. G Rif.2)
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2 (Not active on SAFE 3).
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light