Parameter
min.
max.
CLS. S LWD.
1
99
FORCE
0
1
BRAKE
15
99
OP SPEED
15
50
CL SPEED
OP SLOW
15
30
SPEED
CL SLOW
15
30
SPEED
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABELLA "B" - LOGICHE - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
INSTALLATION MANUAL
Default
Personal
Definition
Leaf/leaves force during
75
closing during slow-down
1
Braking
30
Opening speed [%]
30
Closing speed [%]
Opening slow-down speed
23
Closing slow-down speed
23
Cross out
Default
setting
used
0
0
 
1
0
0
 
1
0
1
0
 
2
0
0
 
1
Force exerted by leaf/leaves during closing at slow-down speed.
This is the percentage of force delivered, beyond the force stored during
the autoset cycle (and subsequently updated), before an obstacle alarm is
generated.
The parameter is set automatically by the autoset function.
[%]
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Enables stopping by injecting direct current in the event the safety edge
is tripped
Percentage of maximum speed that can be reached by motor(s) during
opening.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING:
when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING:
when the display reads "SET", obstacle detection is not active.
Opening speed of motor(s) during slow-down stage, given as a percentage
of maximum running speed.
WARNING: Once the parameter has been edited, a complete
[%]
uninterrupted opening-closing cycle is required. WARNING: when
the display reads "SET", obstacle detection is not active.
"Closing speed of motor(s) during slow-down stage, given as a percentage
of maximum running speed.
WARNING: Once the parameter has been edited, a complete
[%]
uninterrupted opening-closing cycle is required. WARNING: when
the display reads "SET", obstacle detection is not active.
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
SIRIO CBA 230 INV
4 STEP
OPENS
STOPS
CLOSES
OPENS
21
-