Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select Mode option. Press the controller.
Rotate the controller to select icon
"Forest") or
(mode "Identification").
Press the controller to confirm.
Icon of the selected mode is shown in the status bar in the lower portion
of the display.
Selection of calibration mode
Please read detailed description in the section "Switching on and
calibration" in section 8 "Operation".
Brightness setting of menu icons
Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select icon
Rotate the controller to select brightness level of icons from 1 to 10.
To exit the main menu, keep the controller pressed for two seconds or
wait 10 seconds to exit automatically.
Selection of menu color
Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select icon
Available menu colors are: white, red, green, blue.
Along with the color change of menu icons, the color of pop-up symbols
and icons in the status bar change.
Selected color of menu icons is saved in the memory of your thermal
scope after it is turned off.
Automatic shutoff (XQ series only)
Automatic shutoff is actuated when you incline your scope at more than 70
degrees upwards or downwards relative to the optical axis. The unit turns
off automatically after the time set in the menu expires.
Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select icon
Select a period of time after which the scope will automatically turn off: 1
min; 3 min or 5 min. A respective icon appears in the status.
To deactivate the function, select icon "OFF".
TAB M2 FUNCTIONS:
Selection/disable of video output signal (XQ series only)
Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select icon
Rotate the controller to select video output signal – PAL or NTSC
(video output is off by default).
To disable the video output, select "OFF". Disabled video output
reduces power consumption of the thermal imager.
To exit the main menu, keep the controller pressed for two seconds or
wait 10 seconds to exit automatically.
12
(mode "City") or
(mode
. Press the controller.
. Press the controller.
. Press the controller.
. Press the controller.
Clock Set Up (XQ series only)
Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select icon
Move the cursor by rotating the controller to select time format "24" or
"AM/PM".
Press the controller to proceed to hour setup. Set the hour by rotating
the controller.
Press the controller to proceed to minute setup. Set the minute by
rotating the controller.
To exit main menu, press and hold the controller for two second. Or
wait 10 seconds to exit automatically.
Defective pixel repair
When operating a thermal imager, defective (dead) pixels (bright or dark
dots with constant brightness) may appear on the detector, which are
visible on the image. Thermal imagers Quantum allow the user to repair
defective pixels on the detector using a software-based method.
Press and hold the controller (2) for two seconds to enter the menu.
Rotate the controller to select icon
Select icon
in the pop-up submenu and press the controller.
A red cross
appears in the centre of display, coordinates (X;Y)
X=50
of the cross relative to the centre of display appear in the place of
Y=50
pop-up icons, icons disappear.
Rotate the controller to align the cross with a defective pixel (defective
pixel should go out).
Switch direction of the cross from horizontal to vertical by a short
press of the controller.
After the centre of the cross is aligned with a defective pixel, press the
"Mode" (4) button to repair a pixel.
In case of success a short "OK" message appears in place of the
coordinates.
Further on, move the cross to repair another defective pixel. When
moving the cross to the coordinates area, the latter goes to the lower
right portion of the display.
Return to default defective pixel pattern
If you wish to return to the default defective pixel pattern (i.e. restore
all defective pixels previously repaired), select icon
up submenu and press the controller.
Options "Yes" and "No" appear on the right of the icon.
Rotate the controller to select "Yes" and press the controller.
If you choose not to return to default pixel pattern, select "No" and
press the controller.
To exit the main menu, keep the controller pressed for two seconds or
wait 10 seconds to exit automatically.
Attention! One or two pixels in the form of bright white or colour (blue,
red) 1-2 pixels dots are allowed on the display of thermal imager. These
pixels cannot be repaired and are not a defect.