Functions of the controls
Controls
Operating mode
1st short press
name
Scope is off
Scope is on
Button
ON
Scope is on
Display off
Display on
Button
Cal
Display off
Scope is on
Button
Mode
Scope is on
Button
Rangefinder is on
RF
Brightness
Pass to "Contrast"
mode
Controller
Contrast
Pass to "Brightness"
mode
Rangefinder
5
MENU AND STATUS BAR ICONS:
Operating mode "City"
Operating mode "Forest"
Operating mode "Identification"
M
Manual calibration mode
H
Semiautomatic calibration mode
A
Automatic calibration mode
Video output signal selection PAL/NTSC or video output disable
Clock setup
Brightness setting of menu icons
2х full magnification
Defective pixel repair option
Cross for defective pixel repair
Brightness and contrast setup
Image inversion modes: "White hot"/"Black hot"
Color modes
Stadiametric rangefinder
Return to default defective pixel pattern
Low battery indicator
Operation on external power supply
Automatic power off
6
Subsequent short
Long press
Rotation
press(es)
Display off
Scope is off
Display on
Scope calibration
Calibration is not executed
Zoom
Color mode
change
Rangefinder is off
Pass to "Brightness"
Changing
mode
brightness
value
Enter the menu
Changing
Pass to "Contrast" mode
contrast
value
Changing
distance
value
Status bar
The status bar in the lower part of the display shows information as
follows:
Operating mode: City, Forest, Identification.
Calibration mode: Manual, Automatic, Semi-automatic.
Automatic power off. Displayed only when the function is activated.
Image inversion mode. Displayed only when "Black Hot" color mode
is selected.
Zoom. Shows the value of the full optical magnification.
Clock setup. Shows running time in a 12h or 24h format.
Power. Shows current battery status or connection on an external
power supply.
The functions are shown on the display as follows:
Mode
6

INSTALLATION OF BATTERIES

Turn the lever of the battery compartment (11) 90 degrees in "Open"
position and, pulling by the lug of the cover, remove the battery
container.
Install four AA batteries (or rechargeable batteries) observing polarity
shown on the battery container.
Insert the battery container into the battery compartment and turn the
lever 90 degrees clockwise.
Battery charge level is displayed in the status bar (
In case of complete battery discharge, icon
status bar and in the centre of the display.
Note: to ensure long and reliable operation it is recommended that you
use quality rechargeable batteries with a capacity of at least 2500 mAh.
Please do not use batteries of different types or batteries with various
charge levels.
7

EXTERNAL POWER SUPPLY

The scope can be powered with an external DC power supply (2.1mm
pin) with stabilised voltage ranging from 8.4V to 16V or a 12V vehicle
socket.
Connect the plug (16) of the cable
to the jack (10) of the scope by
matching the notch in the plug
connector and the protrusion of the
jack (10) (see the scheme).
Cal
х2
).
is flashing in the
7