Fault
Engine is sputtering.
(runs erratically)
Decreasing engine power.
Cutting performance decreases.
Branches are not automatically
drawn in into the side hopper.
Unusual noise or vibrations.
Please observe the enclosed terms of guarantee.
22
Possible cause
Choke lever set to "
Position
Spark plug connector not firmly placed on.
Vent in the tank cap blocked.
Fuel old or contaminated.
Incorrect carburetor adjustment.
Machine overloaded.
Machine is blocked.
Air filter contaminated.
Internal fault.
Knife edges became blunt.
Beaters worn.
V-belt slipping.
Knife edges became blunt.
Screws, nuts or other parts loosened.
G
G
u
u
a
a
Remedy
"
Set choke lever to "
Firmly place on the spark plug connector.
Clean the tank cap and the vent.
Drain the fuel into a container outdoors. Fill the tank with
fresh and clean fuel.
Have the caburetor adjusted correctly.
a) Reduce material feeding.
b) Do not exceed the max. branch diameter.
Thoroughly clean inside the machine.
Clean or replace filter elements
Contact the manufacturer or the responsible customer
service respectively.
Turn the knife or replace it with a new set of knives.
Replace the beaters.
Tension the V-belt.
Exchange knives.
Tighten the parts.
If the parts can not be tightened or noises remain:
Contact the manufacturer or the responsible customer
service respectively