Technical Data - ProMinent CONCEPTplus CNPa Instrucciones De Servicio

Idiomas disponibles

Idiomas disponibles

Technical data

10

Technical data

Output table CNPa for 180 strokes/min
Type
Minimum pump
capacity
at maximum back
pressure
bar
l/h
concept
plus
1000
10
0.74
1601
16
1.1
1002
10
2.1
0704
7
3.9
0308
3
8.5
0215
1.5
14.9
concept
metering pumps with self-bleeding dosing head SER***
plus
1002
10
1.8
0704
7
3.0
0308
3
9
0215
1.5
13.2
50
Minimum pump
capacity
at medium back pres‐
sure
ml/
bar
l/h
stroke
0.07
5.0
0.97
0.10
8.0
1.4
0.19
5.0
2.6
0.36
3.5
4.4
0.79
1.5
10.8
1.38
1.0
17.6
0.17
5.0
2.7
0.28
3.5
3.9
0.83
1.5
13.2
1.22
-
-
Connector
size
outside Æ
x inside Æ
ml/
mm
stroke
0.09
6x4
0.13
6x4
0.24
6x4
0.41
6x4
1.20
8x5
1.70
8x5
0.25
6x4
0.36
6x4
1.2
8x5
-
8x5
Suc‐
Pri‐
Max.
tion
ming
priming
lift*
lift**
pres‐
sure on
the
suction
side
m WS
m WS
bar
6.0
1.8
8
6.0
2.0
8
5.0
2.5
5
4.0
3.0
3
2.0
2.0
1
1.5
1.5
0.5
5
1.8
5
4
1.8
3
2
1.8
1
1.5
1.8
0.5
loading