E) Thermostat valve (Fig. 3)
- Pull out the pipe from its sheath (Fig. 3 position L)
- Remove the gas pipe from the valve outlet
- Undo the 4 screws of the upper gas inlet flange
ATTENTION: Carefully check the O.R. gas seal.
- Remove the thermocouple with a 9mm-spanner.
- Remove the pilot burner gas supply pipe by using a 10mm-spanner.
- Change the old thermostat valve with a new one.
ATTENTION: The buttons must be on the top side ; do not forget the thermocouple interruption !
- Mount everything back by following the reverse order.
- Adjust the bypass idle screw (100% open!)
- Mount back the valve pipe and the limit thermostat bulb (Fig. 3 position M)
ATTENTION: Check the gas seal with soap bubbles.
- Check that the oil temperature reaches 195°C with the thermostat on position 8.
F) Burner (Fig. 1)
- Disconnect the gas supply pipe
- Remove the screws with a spanner of 8 mm.
- Now you can replace the burner.
- Mount everything back by following the reverse order.
ATTENTION: Check the gas seal with soap bubbles.
G) Safety thermostat (Pos. Z)
- Check the operation and find the reason causing the thermostat to come on. Its replacement is very easy.
ATTENTION : The thermostat interrupts the thermocouple circuit.
5.
FOREWORD
Before operating this device, wash thoroughly the inner part of the container with warm water and detergent and rinse
repeatedly.
Open tap (N) to fill the container. Water will be supplied by tap (E).
Never use large crystals of salt ; it may deposit on the bottom of the container and because of its heavy weight, may not be
completely dissolved. In the long run, all salt not dissolved may generate corrosion problems on the contact spot. Please use
small crystals of salts (less than 3 mm) only after boiling. If this is not possible and the salt to be dissolved has large crystals,
dissolve it in warm water in a separate container.
5.1
IGNITING THE PILOT (FIG. 3)
- Open the gas valve supplying the unit.
- Turn the temperature regulating knob (R) and bring it to Position (
- Press and keep the pilot (N) button pressed until ignition occurs, and at the same time press the ignition button several
times for 20 seconds, until all the air contained in the piping is expelled and the pilot ignites (you can check that by
looking through the open unit door).
GB
).
- 16 -
USER INSTRUCTIONS