L1
Antenna
L2
Antenna shield
Opening command for a standard
L3
connection device with switch
normally open.
Pedestrian opening command for a
L4
standard connection device with
switch normally open.
L5
STOP command. N.C. switch
L6
Photocell. N.C. switch
Edge. Switch N.C. or resistive rubber
L7
edge
L8
Commands common (-) line
24 VAC power output for photocells
L9 - L10
and other accessories
Power supply for functional test TX
L10 - L11
photocell
ELECTRICAL CONNECTION TABLE
20
K1 - K2
Courtesy light timer activation switch
K3
Motor 1 open
K4
Motor 1 common
K5
Motor 1 close
K6
Motor 2 open
K7
Motor 2 common
K8
Motor 2 closed
K9 - K10
230V - 40W / 120V - 40W blinker
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
J1
NOT USED
PLEASE NOTE: If not used, the normally closed
inputs (STOP, PHOTO, EDGE) must be jumpered
with the commands common line COM (-)