City2 Function Table - V2 City2 Instrucciones

Cuadro de maniobras digital para cancelas de 1 ó 2 hojas para motores de 24v
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

DISPLAY
DATA
dEF.
no/Si
t.AP1
0.5" ÷ 2.0'
t.AP2
0.5" ÷ 2.0'
t.APP
0" ÷ t.AP1
t.Ch1
0.5" ÷ 2.0'
t.Ch2
0.5" ÷ 2.0'
t.ChP
0" ÷ t.Ch1
r.AP
0.5"÷ 2.0'
r.Ch
0.5" ÷ 2.0'
t.SEr
0.5" ÷ 3.0"
no
t.inv
0.5" ÷ 3.0"
no
t.PrE
0.5" ÷ 2.0'
no
Pot1
1A ÷ 7A
Pot2
1A ÷ 7A
P.raL
no/Si
F.rAL
no
vEL2
vEL1
St.AP
PAUS
ChiU
no
St.Ch
Stop
APEr
St.PA
ChiU
no
SP.AP
PAUS
ChiU
no
Ch.AU
no
0.5" ÷ 2.0'

City2 FUNCTION TABLE

DESCRIPTION
Load V2 ELETTRONICA standard data
Gate 1 opening time
Gate 2 opening time
Opening time of pedestrian gate
Gate 1 closing time
Gate 2 closing time
Closing time of pedestrian gate
Gate delay during opening
Gate delay during closing
Electrical lock operation time
- Lock is not energized (it corresponds to 0)
Backlash time
- Disabled recoil (it corresponds to 0)
Pre-flashing time
- Disabled pre-blink (it corresponds to 0)
Under stress motor 1 alarm threshold (it deals with a conventional number)
Under stress motor 2 alarm threshold (it deals with a conventional number)
Start slowing down.
End of stroke slowing down
- Disabled slowing down.
- Motor slowing down at speed 2.
- Motor slowing down at speed 1.
Start in opening
- Stop the gate and goes in pause
- Command close gate
- Start command is not available
Start in closing
- Start command stop the gate
- Start command open the gate
Start in pause
- Start command closes the gate
- Start command is not available
Pedestrian in opening
- Gate goes in pause
- Pedestrian start command closes the gate
- Pedestrian start command is not available
Automatic closing
- The automatic closing is not active (it corresponds to 0)
- The gate closes after the setup time)
26
DEFAULT
MEMO
DATA
DATA
no
22.5"
22.5"
6.0"
25"
25"
7.5"
1.0"
3.0"
1.0"
no
1.0"
3.0A
3.0A
no
no
PAUS
StoP
ChiU
PAUS
no
Tabla de contenido
loading

Este manual también es adecuado para:

City2-120v

Tabla de contenido