START INPUT
The START input is preset for connecting devices
with the switch normally open.
Function depends on the mode of operation set by
means of dip-switch 4.
Step mode
Subsequent Start command cause, in order:
opening
stop
closure
"Inversion" mode
Start during opening causes closure.
Start during closure causes opening.
Start with the gate open always results in closure;
The only case where this does not occur
immediately is when automatic closure is enabled
and start while opening is not accepted: in this
specific case, start makes the pause time count start
from zero, after which the gate will be re-closed.
In both modes it is possible to disable the Start
command during gate opening by means of
dip-switch 3.
Connect the start input control device cables
between terminals L3 and L8 on the control unit.
PEDESTRIAN START
With the gate closed, the pedestrian start command
causes partial opening (approx. half way) of the
gate leaf connected to motor 1. Subsequent
pedestrian start commands will function according
to step logic.
During a pedestrian cycle, the start command results
in the complete opening of both gate leaves.
Connect the pedestrian start input control device
cables between terminals L4 and L8 on the control
unit.
stop
STOP
The STOP input is intended for devices with the
switch normally closed.
The STOP command causes the immediate stop of
the gate.
A subsequent START command activates the gate in
the opposite direction of movement.
If the STOP command is given during opening or
pause, then there will be no subsequent automatic
re-closure.
Connect the stop input control device cables
between terminals L5 and L8 on the control unit.
18