The START1 input impulse is not accepted when
ON
opening (Condominium Logic)
Dip 5
The START1 input impulse is accepted even when
OFF
opening
The input impulse on opening/closure causes
ON
direction change
Dip 6
The input impulse on opening/closure causes stop
OFF
(Step-Step Logic)
3. Standard Function (Dip 1 OFF / DIP 2 OFF)
The following options are available:
Up-Down Operation (Dip 3 ON)
START1 controls opening (open-stop-open-stop)
START2 controls closure (close–stop-close-stop)
Start-Stop Operation (Dip 3 OFF)
START1 controls opening and closure (open-stop-close-stop)
START2 is disabled
Automatic Closure (Dip 4 ON)
Enable closing at the end of the pause time
Condominium Operation (Dip 5 ON)
Open commands are ignored if the shutter is already opening
Inversion mode (Dip 6 ON)
If Start-Stop operation is enabled, START1 changes the direction
of the motion during opening and closing instead of stopping the
shutter
Dip 1 OFF DEAD MAN function disabled
Dip 2 OFF Clock Function disabled
Individual Controls: START1 opens, START2 closes
ON
(up-down)
Dip 3
OFF Unified Controls: START1 opens and closes (start-stop)
ON Automatic Closure Enabled
Dip 4
OFF Automatic Closure Disabled
ON START1 ignored when opening (Condominium Logic)
Dip 5
OFF START1 accepted when opening
"Direction Change"
ON
Logic
Dip 6
OFF Step-Step Logic
Connect the wires of the device that controls the START1 input
between terminals L3 and L8 on the controller.
Connect the wires of the device that controls the START2 input
between terminals L4 and L8 on the controller.
Only applied to the START1
input when in the Start-
Stop mode.
STOP
The STOP input is intended for devices with the switch normally
closed. The STOP command causes the immediate stop of the
roller shutter.
If the STOP command is given during opening or pause, then
there will be no subsequent automatic re-closure.
Connect the stop input control device cables between terminals
L5 and L8 on the control unit.

PLUG-IN RECEIVER

The control unit is suitable for plugging-in an MR1 series receiver
with high sensitivity super-heterodyne architecture.
PLEASE NOTE: Disconnect the power to the control unit
before performing the following operations. Pay the utmost
attention to the direction of insertion of plug-in modules.
The MR1 receiver module has 4 channels, each with an
associated command on the control unit:
• CHANNEL 1
START1
• CHANNEL 2
START2
• CHANNEL 3
STOP
• CHANNEL 4
COURTESY LIGHTS
The functional logic for channels 1 and 2 is the same as that set
for the START1 and START2 inputs on the terminal board.
PLEASE NOTE:
Read the instructions supplied with the MR1 receiver thoroughly for
details on programming the 4 channels and the operational logic.

EXTERNAL ANTENNA

It is recommended the external antenna be used in order to
guarantee maximum radio capacity.
Connect the antenna hot pole to terminal L1 of the control unit
and the braiding to terminal L2.
11