PLEASE NOTE: If not used, the normally closed inputs (STOP, PHOTO, EDGE) must be jumpered with the commands
common line COM (-). Disable the functional test for photocells and safety devices (Dip 9 and 12 in the OFF position)
L1
Antenna
L2
Antenna shield
START1 - Activation input 1 for connection to
L3
traditional devices with NO contacts (open/close)
START2 - Activation input 2 for connection to
L4
traditional devices with NO contacts (close/timer)
L5
STOP command. N.C. switch
L6
Photocell. N.C. switch
L7
Edge. Switch N.C. or resistive rubber edge
L8
Commands common (-) line
Power output 24 Vac for RX photocell and
L9 - L10
accessories
L10 - L11 Power supply for functional test TX photocell
ELECTRICAL CONNECTION TABLE
J1

FAULT MESSAGES

At the start of each operating cycle, the controller performs an
operational test of the motor drive circuit (Triac). Furthermore, if
enabled by the relative dipswitch, it also performs a test of the
photocell and safety device inputs.
If a fault occurs, the cycle does not start.
The messages are indicated by the blinker:
• Blinks about 4 seconds: Triac fault (or motor disconnected)
• Blinks about 8 seconds: Photocell or safety device fault
8
C1
Motor open
C2
Motor common
C3
Motor close
D1 - D2 Courtesy light timer activation switch
D3 - D4 230V - 40W / 120V - 40W blinker
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
J1
NOT USED