Plug In Receiver - V2 EASY-TOP Manual Del Usuario

Cuadro de maniobras digital para persianas enrollables
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
L1
START/UP. N.O. contact
L2
STOP. N.C. contact
L3
COMMON (-)
L4
DOWN. N.O. contact
L5
PHOTOCELL. N.C. contact
EDGE. N.C. contact
(Safety edge - parameter
L6
FCA. N.C. contact
(Opening limit switch - parameter
FIRE. N.C. contact
in5
(Alarm - parameter
L7
FCC. N.C. contact
(Closing limit switch - parameter
L8
COMMON (-)
L9
Adjustment of the power for OPTICAL SAFETY EDGE
30 Vdc power output for photocells and
L10
other accessories
30 Vdc power supply for functional test
L11
TX photocell
Flashing light 230Vac / 120Vac
ou1
oFF
(parameter
=
E1 - E2
Courtesy light 230Vac / 120Vac
ou1
on
(parameter
=
E3
Motor open
E4
Motor common
E5
Motor close
N
230Vac / 120Vac power supply - neutral
L
230Vac / 120Vac power supply - phase
A1
Antenna shield
A2
Antenna
in5
oFF
=
)
in5
on
=
)
oFF
=
)
in5
on
=
)
)
)
OPTICAL EDGE INSTALLATION
The EASY-TOP main control unit is configured for the installation
of one 24 Vdc powered optical edge and transmitter power
regulation.
Connect the transmitter and receiver in accordance
with the following table.
TRANSMITTER
L6
L8
BLUE CABLE
L9
BLACK CABLE
L10
L11
BROWN CABLE
After having made the connections, power-up the main control
unit and adjust the power using the trimmer TR1 located on the
control unit so as to obtain optimal edge operation.
FIRE / ALLARM INPUT
Safety input for connecting a fire or other type of alarm requiring
the immediate automatic opening of the door.
The FIRE command should be connected between the FIRE (L7)
and COMMON (L8) terminals.
When the FIRE contact is opened, the door is opened and cannot
be closed again until the contact is reset.
NOTE: If the input is set as an alarm (
contact is open, the port cannot be opened. If the port is already
open, it is closed.

PLUG IN RECEIVER

The control unit is suitable for plugging in a MR receiver.
MR module receiver is provided with 4 channels and each of
them is suitable for a command of the control unit:
• CHANNEL 1
START/UP
• CHANNEL 2
STOP
• CHANNEL 3
DOWN
• CHANNEL 4
COURTESY LIGHT
WARNING: Before programming 4 channels and
function logics read carefully the instructions of MR
11
RECEIVER
BLACK CABLE
BLUE CABLE
BROWN CABLE
in4
oFF
=
), when the FIRE
Tabla de contenido
loading

Tabla de contenido