BRASS Akron STYLE 3600 Instrucciones De Instalación Y Operación página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

• Security Code: 64-bit code from serial number of module
NOTE: Enclosing the receiver in a compartment or behind the pump panel will reduce the effective range.
MECHANICAL ATTACHMENT OF RECEIVER
Below are the mounting holes dimensions for the receiver. Mount the receiver to allow enough cable for proper installation to the Logic Box
(see Electrical Layout). The receiver will come with a 10 foot cable.
1.33"
3.89"
ELECTRICAL INSTALLATION OF RECEIVER
The following table is used for connecting the Receiver to the U1 Logic Box. The color-coded wires should be connected to the appropriate
terminal of the Logic Box.
Receiver
Terminal Position
Wire Colors
White
White/Black
Brown
Yellow
Green
Blue
Red
Black
White/Red or
White/Brown
Orange
Purple
Gray
* The AUX button on the handheld can be used for STOW, DEPLOY or OSCILLATION, if available on the monitor. Connect the White/Red wire
to the corresponding terminal of the logic box for the function requested by the customer. See monitor operating instructions or logic box
lid label for wiring diagram and terminal location.
** Connect a jumper wire from TB3-07 (relay common contact) to TB3-03 (+system voltage) in order to have the AUX LED on the handheld
controller indicate if the monitor is stowed or deployed.
• AUX LED ON – Deployed
• AUX LED OFF – Stowed
2
U1
Logic
Box
(U1 Logic Box)
TB1-10 or TB2-2
Power In – from Vehicle Battery (+12/24V)
TB3-15 or TB2-3
Power In – from Vehicle Battery (−)
TB1-01
Output – to FOG input of logic box
TB1-02
Output – to STREAM input of logic box
TB1-03
Output – to UP input of logic box
TB1-04
Output – to DOWN input of logic box
TB1-05
Output – to LEFT input of logic box
TB1-06
Output – to RIGHT input of logic box
*
Output – AUX1 to STOW/DEPLOY/OSC input from AUX button on handheld
TB1-21
Output – to STOW input of logic box (for SIT use only)
TB1-22
Output – to DEPLOY input of logic box (for SIT use only)
TB3-08**
Input – from STOW/DEPLOY relay to AUX LED on handheld
DEPLOY
ELECTRICAL LAYOUT
Receiver
10 ft.
Cable
Function
SS
RIGHT
RAISE
FOG
LEFT
LOWER
STOW
READ OPERATING INSTRUCTIONS BEFORE USE
WARNING
DO NOT DEPRESS STOW OR DEPLOY
WHILE FLOWING WATER
DEPLOY
SS
RIGHT
FOG
LEFT
STOW
READ OPERATING INSTRUCTIONS BEFORE USE
WARNING
DO NOT DEPRESS STOW OR DEPLOY
WHILE FLOWING WATER
RAISE
LOWER
Tabla de contenido