1.1 INTRODUCTION
Please read it carefully before installing the appliance, before using it and before routine or extraordinary maintenance work.
The notices preceded by this symbol provide important information, the non-compliance with such instructions voids the
manufacturer's guarantee.
OPERATIONS THAT, IF NOT CARRIED OUT CORRECTLY, CAN BE RISKY, ARE INDICATED WITH THE FOLLOWING SYMBOLS
The INSTALLATION, USE AND MAINTENANCE handbook is for installers, users and maintenance engineers
The Company is not liable for injury to people or animals or damage to things in the case of applications that exceed the limits specifi ed on
the enclosed technical data sheet or by a use diff erent from what the appliance has been designed.
1.2 GENERAL SAFETY
•
Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags
out of children's reach.
•
Do not install the product in explosive atmosphere.
•
Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buff er batteries, if fi tted.
•
Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3,5 mm.
•
Check that a diff erential switch with a 0,03A threshold is fi tted just before the power supply mains.
•
Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and
shearing, according to and in compliance with the applicable directives and technical standards.
•
The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturer's components are used.
•
Only use original parts for any maintenance or repair operation.
•
Do not modify the automation components, unless explicitly authorised by the Company.
•
Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
•
Do not allow persons or children to remain in the automation operation area.
•
Keep radio control or other control devices out of children's reach, in order to avoid unintentional automation activation.
•
Anything which is not expressly provided for in the present instructions, is not allowed.
1.3 GENERAL
The automatic electromechanical barrier is designed to control passage openings up to 8 metres wide in compliance with European standards. It is
suitable for industrial applications and it is the ideal solution for managing vehicle traffi c.
1.4 TECHNICAL SPECIFICATIONS
Power ............................................................................................................230Vac/115Vac ±10% 50/60Hz
Motor ..............................................................................................................230Vac 900RPM 14uF 0.50kW
Absorbed power .......................................................................................................................................... 650W
Control unit ......................................................................................................................................CSB-Xtreme
Impact safety ............................................................................................................................................Encoder
Opening time ....................................................................................................................................4.5 ÷ 6.0 s
1.5 OVERALL DIMENSIONS
590
590
170
360
170
360
1. General information
ELECTROCUTION
60
360
60
400
CRUSHING
Arm length ................................................................................................................................................4 ÷ 8 m
Working temp .................................................................................................................................... -30 +60°C
Manoeuvres in 24h ......................................................................................................................................3000
Protection level ............................................................................................................................................. IP 65
Weight ........................................................................................................................................................~110 kg
LEFT barrier
- 9 -
EN
RIGHT barrier