Connection For Measuring Element - ABB TTF300 Instrucciones Para La Puesta En Funcionamiento

Transmisor de temperatura para montaje en campo
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 105
4.3

Connection for measuring element

Important
The measuring element is connected via sensor connecting cable. The sensor connecting
cable is not delivered with the transmitter. It must be ordered as a separate accessory.
The model of the sensor connecting cable must correspond to the sensor model and
configuration of the transmitter.
When connecting the transmitter and measuring inset (sensor) make sure for thermocouple
sensors that the material of the sensor connecting cable corresponds to the thermocouple
model.
1. Look for the connection type for the selected measuring element in the electrical connections
for measuring elements.
2. Release the clamping screws for terminals 1 to 6 using the proper screwdriver. Make sure
that the screws do not fall out.
3. Insert the wires for the measuring element and sensor cable connection under the open
terminals and carefully tighten the clamping screws for the connections.
CI/TTF300-X1
TTF300
Electrical connections
EN - 15
Tabla de contenido
loading

Tabla de contenido