XR200 sensors has only a transmission activity in the system; every transmission
includes all the following informations:
! Contact Status
! NC Line Status
! 24h Protection Tamper Status
! Battery Status
The change of one listed parametre causes the integral transmission of the
informations. This transmission happens only at the opening of the contact or of the
NC line, it cause the flash of the Sensor green LED to indicate the transmission of the
informations to the Central Unit (the red LED replaces the green LED if the battery is
flat).
When the protection zone is open, this information arrives at the Central Unit and it is
signalled by the lighting of the Zones Control LED ( , o ).
The closing of the contact or of the NC line don't cause effect.
If the Zone remains open, or if it is closed, no informations are sent up to the next
opening.
-
the XR152 detectors have only a transmission activity; every transmission includes all
the following informations:
! detection
! 24h protection tamper status
! battery status
The change of a listed parametre causes the integral transmission of the
informations. This transmission happens only during the detection which causes the
lighting of the detector green LED to indicate the transmission of the informations to
the Central Unit (the red LED replaces the green LEd if the battery is flat).
When the detection starts, the information of the Zone opening arrives at the Central
Unit and it is signalled by the lighting of Zones Control LED ( , o ).
After the detector is inhibited for 5 minutes.
On enabled system, NC line opening put in action an alarm cycle.
!
This alarm cycle is in action for all alarm time setted in the programming mode.(par.
!
3.1.2.3).
If NC line isn't resetted, the alarm cycles are intervalled by 10 seconds pause.
!