XR500 - User's Manual
3.1.2
Times Regulations
LED lit
LED blinking
In this mode, "INSERITO" (Enabling) LED is lit, "ALLARME" (Alarm) LED blinks, and
"CONTROLLO ZONE" (Zones Control) LEDs 1, 2 and 3 blink.
If the System Code is not programmed, skip this procedure pressing "STATO ZONE /
MEMORIA ALLARME" (Zone Status/Alarm Memory).
3.1.2.1 Exiting Time Regulation
Holding down "ESCLUSIONE" (Exclusion) Zone 1 button, the Zone
1, 2 and 3 LEDs turn off; the Exiting Time is setted to zero and Zone 1
LED starts to blink. Each blink of Zone 1 LED rises the Exiting Time of 1
second. If the button is released at first blink, the Exiting Time will be
setted to 0 sedonds; if it is released over 60 blinks, the Exiting Time will
be setted to 60 seconds (max.value).
Default Exiting Time is 3 seconds.
3.1.2.2 Entering Time Regulation
Holding down "ESCLUSIONE" (Exclusion) Zone 2 button, the Zone
1 and 3 LEDs turn off; the Entering Time is setted to zero and each blink
of Zone 2 LED rises the Entering Time of 1 second. If the button is
released at the first blink, the Entering Time will be setted to 0 seconds; if
it is released over 60 blinks, the Entering Time will be setted to 60
seconds (max.value).
Default Entering Time is 4 seconds.
3.1.2.3 Alarm Time Regulation
Holding down "ESCLUSIONE" (Exclusion) Zone 3 button, the Zone
2 and 3 LEDs turn off; the Alarm Time is setted to 180 seconds
(max.value).Each blink of Zone 3 LED rises the Alarm Time of 10
seconds. If the button is released at the first blink, the Alarm Time will be
setted to 180 seconds (3 minutes); if it is released over 42 blinks, the
Alarm Time will be setted to max. value of 600 seconds (10 minutes).
Default Alarm Time is 180 seconds (3 minutes).
Press "STATO ZONE / MEMORIA ALLARME" (Zone Status / Alarm Memory) button to
enter in the next programming mode: Settings
36
antifurtoriginale.it
ST/BY
RETE
POWER
ASSENZA RETE
MAIN POWER
INSERITO
ARMED
ALLARME
ALARM
FLASH:
MEMORIA ALLARME
MEMORY ALARM
XR500
24h
CENTRALE
CENTRAL
SENSORI
STATO ZONE
SENSORS
ZONE STATE
SIRENE
SIRENS
RX / TX
MEMORIA
ALLARME
ALARM
MEMORY
ZONE CONTROL
ON
FLASH
ZONA APERTA
ZONA ESCLUSA
ZONE ESCLUSED
ZONE OPENED
OFF
LAMP: ZONA
ZONA CHIUSA
ALLARMATA
Zone alarmed
CLOSED ZONE
E X C L U S I O N
security