Troubleshooting Table - Kohler K-8034 Guia De Instalacion

Ocultar thumbs Ver también para K-8034:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Connect Panel to the PDS (cont.)
IMPORTANT! Verify all unused holes of the PDS box have the
plugs installed.
Verify all wires are tucked into the PDS housing and will not be
pinched when securing the access cover.
Reinstall the access cover. Do not overtighten.
Connect the chroma data cable to the media module or steam
adapter. Refer to the media module or steam adapter installation
guide.
Turn on the power supply to the PDS.
Refer to the Digital Interface User Guide to test the overhead rain
panel for proper functionality.
Troubleshooting
This troubleshooting guide is for general aid only. For service and
installation issues or concerns, call 1-800-4-KOHLER.

Troubleshooting Table

Symptoms
Probable Cause
1.
Rain panel
A. No power to PDS.
does not light.
B. No power to
C. Cable connections
D. PDS fuse is blown.
E. Media module is
1078520-2-C
Recommended Action
A. Turn off the power to
the PDS and remove
the access cover. If
the LED light is not
lit, the circuit breaker
may have been
tripped. Reset the
circuit breaker. If the
LED light is still not
lit, check hardwire
connections.
B. Verify media module
media module
is plugged in. Check
(media module
power to the outlet.
status LED is off).
C. Check cables and
to media module
connections, replace
are loose or
cables if necessary.
damaged.
D. Replace the PDS
fuse.
E. Contact a Kohler
not assigning an
Authorized Service
address to the PDS.
Representative.
22