Escutcheon
Socket Wrench
With 11 mm Bit
Waterway
Screw
7. Install the Waterway
CAUTION: Risk of personal injury or product damage. If
the rain panel is not securely held in place during
installation, product may fall causing personal injury or
property damage. Get help when installing the light panel
assembly and waterways.
IMPORTANT! The following steps require two people.
Insert an escutcheon into one of the four openings in the light
panel. Orient the double ribs of the escutcheon toward the center
of the panel.
While one installer holds the light panel in place in the rough
opening, the other installer threads all four adapters onto the pipe
nipples to hang the fixture. Once the adapters are installed, the
panel can be released. The panel will not be tight to the ceiling at
this time.
IMPORTANT! Secure the adapter sufficiently to create a water-tight
seal for the pipe threads.
1078520-2-C
Light Panel
Frame
Finished
Ceiling
Adapter
Extension
Double Ribs
Inside Leak
Shield
14
Notch
Kohler Co.