34. Troubleshooting Procedures

This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Symptoms
1.
Unit does not start or
stop.
2. Water flow surges.
3. Motor starts, all bodyjets
are not functioning.
4. Motor starts, waterfall
does not function.
Waterfall lights do not
5.
work.
6. Unit stops automatically
before 18 minutes.
1032108-2-D
Probable Causes
A. No power to
pump/receptacle/keypad.
B. Harness is blocked.
C. Keypad disconnected from
pump/control box.
D. Keypad does not work.
E. Not enough water in footbath
basin.
F.
Motor/pump assembly does not
work.
G. Control does not work.
A. Not enough water in footbath
basin.
B. Suction is blocked.
C. Harness is blocked.
A. Bodyjet is blocked.
B. Bodyjet butterfly valve wiring
loose or damaged, or butterfly
valve is faulty.
C. Not enough water in footbath
basin (pump cavitates).
D. Keypad does not work.
E. Control does not work.
A. Waterfall is blocked.
B. Waterfall wiring loose/damaged
or butterfly valve is faulty.
C. Not enough water in footbath
basin (pump cavitates).
D. Keypad does not work.
E. Control does not work.
A. Loose or damaged wiring.
B. Power supply for lighting does
not work.
A. GFCI or ELCB has tripped.
Recommended Action
A. Set/Reset GFCI or ELCB. Check
wiring. Refer to installer/dealer.
B. Remove blockage.
C. Reconnect keypad and/or wiring
harness.
D. Replace keypad. Refer to
installer/dealer.
E. Fill basin 3" (7.6 cm) over top of
suction cover.
F.
Replace motor/pump assembly.
Refer to installer/dealer.
G. Replace control. Refer to
installer/dealer.
A. Fill basin 3" (7.6 cm) over top of
suction cover.
B. Remove obstruction.
C. Remove blockage. Confirm
constant pipe pitch between
tower and pump.
A. Remove blockage.
B. Identify source of fault and
correct or replace wiring or
butterfly valve. Check all wiring.
Refer to installer/dealer.
C. Fill basin 3" (7.6 cm) over top of
suction cover.
D. Replace keypad. Refer to
installer/dealer.
E. Replace control. Refer to
installer/dealer.
A. Remove blockage.
B. Identify source of fault and
correct or replace wiring or
butterfly valve. Refer to
installer/dealer.
C. Fill basin 3" (7.6 cm) over top of
suction cover.
D. Replace keypad. Refer to
installer/dealer.
E. Replace control. Refer to
installer/dealer.
A. Identify source and correct. Refer
to installer/dealer.
B. Replace lighting supply box in
tower. Refer to installer/dealer.
A. Set/Reset GFCI or ELCB.
28