12 COMMISSIONING
Following installation, conversion to a dif ferent type of gas or
any maintenance operations, check appliance operation. In the
event of any malfunction, consult the next Paragraph "Trouble-
shooting".
12.1 ELECTRICAL APPLIANCES
Switch on the appliance observing the following procedure :
•
Remove any pans from the cooking zones.
•
Ensure the cooking zones are switched off.
•
Power-up the appliance by means of the main switch on the
appliance: the green indicator lights f ash once (after which
they must not switch on or f ash)
•
Switch on and increase the cooking level of the zones: the
green indicator light for zones must f ash steadily, indicating
the absence of pans.
•
Place a pan of water on each cooking zone: the green indica-
tor light remains steadily illuminated.
•
Select the maximum power setting: after a few minutes the
fan switches on.
•
Check the current values of each phase.
13 TROUBLESHOOTING
FAULT
CAUSE
Insufficient
Unsuitable pans
heating
of
c o o k i n g
zone
Continuous
Defective knob parts
heating
of
cooking zone
at maximum
power
C o o k i n g
Defective pot detection sen-
zone opera-
sor
tes
without
pan.
Small
metal items
heat up
The applian-
Fuses blown or interruption
ce does not
of power supply
switch on
The
fuses
Generator short-circuit
blow
when
the
ap-
pliance
is
switched on
The cooking
Pan diameter smaller than
zone
does
12cm
not heat
Defective generator
If the red and green indicator lights are off:
•
Check the fuses.
•
Power supply main switch disconnected.
•
Insuff cient voltage or incorrect electric connection of the ap-
pliance.
If the red and green indicator lights work:
•
Check and count the green indicator light f ashes. Each long
f ash is followed by a certain number of short
number is the code of the malfunction message detailed in
the following table:
ERROR
CORRECTIVE MEA-
SURE
Use suitable pans
Check/replace
the
part
Replace the generator
Check connections
Replace the generator
Use suitable pans
Replace the generator
f ashes. This
MESSAGE
1
High voltage
2
No power at in-
ductor
3
Generator
ove-
rheating
4
Cooking
zone
temperature
too
high or too low
5
Defective control
unit
6
Internal tempera-
ture too high
7
Cooking
zone
temperature sen-
sor malfunction
8
Faulty power sup-
ply
10
Communication
error
11
Initialization error
12
Failure in mains
current
13
Power
supply
connection error
14
Power
supply
adaptor fault
CAUSE
C O R R E C T I V E
MEASURE
U n s u i t a b l e
Use
suitable
pans,
wrong
pans, check the
or defective in-
inductor
ductor
Faulty inductor
Connect the in-
connection
ductor properly
Air vents bloc-
Check/clear
ked, fan not
vents, clean the
working,
f lter
fan and check fan
clogged, faulty
rotation, clean the
t e m p e r a t u r e
f lter
sensor
Empty pan, de-
Remove the pan,
fective tempe-
switch off the ap-
rature sensor
pliance
and let
the cooking zone
cool down befo-
re switching on
again
Faulty connec-
Check
connec-
tion or defecti-
tion. Check/repla-
ve knob parts
ce the part
Air vents bloc-
Check/clear
ked, fan not
vents, clean the
working,
f lter
fan
and check
clogged, faulty
fan rotation, clean
t e m p e r a t u r e
the f lter, remove
sensor,
close
the external heat
proximity
to
source
external
heat
sources
Sensor short-
Check/replace the
circuit
part
Power supply
Check the power
or
synchroni-
supply
zation failure
LIN or CAN-
Disconnect from
Bus
fault,
power supply and
no
connec-
check
connec-
tion
between
tions
keypad
and
generator
Error
during
Wait approx. 30
initialization of
seconds for the
hardware
appliance to reset
Incorrect con-
Connect the con-
trol unit con-
trol unit to the cor-
nection
rect attachment
Failure
while
Check the power
measuring the
supply connection
mains current
Power supply
Check the power
voltage
too
supply connection
high or too low
Power supply
Check the power
voltage
too
supply connection
high or too low
the
the
21