2. Wrap the threads of the 1/4 in. pressure gauge(included) or plug with thread tape and thread it in the elbow insert
hole.Cut off the expanded portion of the pressure tube.
3. Fill the pump through the pump outlet, fill all piping between the pump and the well, and make sure that all piping in the
well is full. If you have also installed a priming tee in the suction piping, remove the plug from the tee and fill the suction
piping.Replace all fill plugs.
4. Install the pressure regulator(included)into the top of the pumpand close the pressure regulator completely
NOTE: This pressure regulator is a normally-closed valve installed at the discharge of the pump to provide an obstruction to
flow and thereby regulate the pump pressure and provide back pressure for the ejector. Failure to use this item may result in
a loss of prime and/or a low pressure.