NEW DEEP WELL INSTALLATION
4" Or Larger Well
1. Removing the pre-assembled ejector first then removing the pre-assembled nozzle and venturi.
2. Attaching the nozzle and venturi to the ejector
63013
Wrap the threads of the venturi tube (J32P-18/#11) and the nozzle (#01/52) with thread tape.
Use the 5/8 inch socket to thread the nozzle (#01/52) in
the ejector.
63023/63033
Wrap the threads of the venturi tube (J32P-18/#11) with thread tape.
Attach the O-ring on the nozzle (#02) and screw the nozzle (#02) into the venturi tube (J32P-18/#11).
Attach the venturi tube (J32P-18/#11) with the nozzle and O-ring to the Ejector.
the ejector, thread the venturi tube (
10
) in
J32P-18/#11