PREPARATION
X1 Max. submersion depth = 15 m
X2 Min. height of liquid above the
underside of the pump = 20 cm
X3 Min. cross-section = ø40 cm
X4 Minimum separation from
the base of the pump shaft = 1m
• Lower the pump into the pump shaft.
• If the depth is greater than 3 m, clip the power cable to the rope at regular intervals, using
corrosion-resistant clips.
• Tighten the end of the rope firmly after lowering.
Electrical connection
Danger!
• Fix the electrical connection unit by means of 4 screws (9) in a location protected from
splashes. The connection cables (10) must point downwards.
• Plug in the mains power suppy.
EN
Note:
If the power cable is not clamped, it may jam the pump in the pump
shaft when it is being drawn out.
Danger of injury!
Ensure that the electrical connection unit does not come into contact
with water!