Errors Codes - Cebora PLASMA PROF 166 HQC Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 137
4.2.5 ERROR CODES
ERROR DESCRIPTION
Error during USB firmware updating
Start pressed at switch-on or power source
reset (switch to RUN mode)
Cooling liquid over-temperature
Module overtemperature: IGBT 1 / IGBT 2
Flow below minimum limit of cooling liquid
Low pressure in a gas supply channel
Door open in power source or in ignition mo-
dule HV19-1 or HV19-PVC
CNC off, in emergency or not corrected to
the power source
Power tranformer over-temperature
Internal error in the microprocessor memory
The power source does not communicate
with the gas console
The power source does not communicate
with the interface circuit
The gas console does not communicate with
the power source
Direct current below minimum acceptable
Problem with internal clock
Writing error in power source flash memory
Current detected with arc off on IGBT1 mo-
dule
Current over range measurement on IGBT1
module during cutting
Current detected on pilot arc circuit with arc
off
62
CODE
USB
Contact the Cebora assistance service
(Err. 85)
TRG
Switch off the power source, remove the start command
(Err. 53)
and restart the power source.
Check for any blockages in the cooling circuit or torch
pipes. Check the integrity of the pump fuse. Clean the
radiator.
H20 T
(Err. 93)
TH1
Do not switch off the power source. This way the fan will
(Err. 74)
continue to operate for quick cooling. Return to normal
operation is automatic when the temperature returns to
TH2
within normal limits. If the problem continues, contact the
(Err. 77)
CEBORA assistance service.
TH3
(Err. 72)
TH4
(Err. 71)
Check for any blockages in the cooling circuit or torch
H2O
pipes. Check the integrity of the pump fuse. Clean the
(Err 75)
radiator.
Increase the pressure of the corresponding gas by means
GAS LO
of the knob on the front panel of the gas console. Also
(Err. 78)
check the gas supply pressure. This must be around 8 bar.
OPN
Make sure the cover of the power source and/or of the
(Err. 80)
HV19-1 or HV19-PVC unit is correctly closed.
rob
Switch on the CNC, exit the emergency, check the power
(Err. 90)
source-CNC connection.
Do not switch off the power source. This way the fan will
continue to operate for quick cooling. Return to normal
TH0
operation is automatic when the temperature returns to
(Err. 73)
within normal limits. If the problem continues, contact the
CEBORA assistance service.
Err 2
Contact the CEBORA assistance service.
Check the connection between the power source and the
Err 6
gas console. If the problem continues, contact the CEBO-
RA assistance service.
Contact the CEBORA assistance service.
Err 7
Check the connection between power source and gas
Err 9
console. If the problem continues, contact the CEBORA
assistance service.
Contact the CEBORA assistance service
Err 16
Err 26
Contact the CEBORA assistance service.
Err 27
Contact the CEBORA assistance service.
Contact the CEBORA assistance service.
Err 30
Contact the CEBORA assistance service.
Err 35
Contact the CEBORA assistance service.
Err 39
POSSIBLE SOLUTION
Tabla de contenido
loading

Este manual también es adecuado para:

Plasma prof 255 hqc

Tabla de contenido