Vimar ELVOX Videocitofonia 69RS.1 Manual De Instalación página 5

Tabla de contenido
69RS.1
When an electronic unit on the HORIZONTAL BUS is remapped,
assigning it to a pillar, an ID code is in any case occupied on the
pillar. If the electronic unit for POS 1, POS 2, POS 3 is remapped,
the ID 1, 2, 3 cannot be used on the pillar for other electronic units.
In addition, if 3 electronic units are remapped on a VERTICAL BUS,
at most another 11 electronic units can be installed on this VER-
TICAL BUS. Unlike the Elvox Due Fili, 14 instead of 15 electronic
units can be used on the VERTICAL BUS. The identification ID =
15 is reserved.
Note: the electronic unit that is in POS 1 in programming will always
be seen by the BUS as a MASTER electronic unit even if remapped
with another ID number.
The electronic units connected to the HORIZONTAL BUS can be
configured by assigning the identification ID from 1 to 36.
Remapping relays
Up to 50 relay modules art. 69PH, for a total of 100 relays, can
be used on the HORIZONTAL BUS. As with the electronic units, a
remapped relay is physically connected to the HORIZONTAL BUS
and via the 69RS.1 interface it can receive commands sent from an
indoor station (on the VERTICAL BUS).
Relays connected on the VERTICAL BUS can operate as a relay
or call repeater.
Relays connected on the HORIZONTAL BUS can operate as a
relay.
Example: Connect the interface 692I/U to a PC with the SaveProg
software installed, connect the 692I/U to the relevant 69RS.1 inter-
face (in the example we have chosen the 69RS.1 interface ID = 1)
and launch the SaveProg program, with the programming software
(Figure 2) in the Remapping Relays window there are the relays to
remap (from 1 to 8) the identification ID = 1 is remapped for exam-
ple with the ID code = 3000.
Activating the function related to relay 1, from an indoor station, re-
ferring to the expansion interface ID = 1 will activate the relay mod-
ule with ID = 3000 on the HORIZONTAL BUS (ID = 5999 / 6000).
NOTE: If on pillar 1 referred to the expansion interface with ID = 1
there is a relay with ID = 1, there will be simultaneous activation of
the relay on the VERTICAL BUS with ID = 1 and of the relay on the
HORIZONTAL BUS with ID = 3000.
The relays connected to the HORIZONTAL BUS can be configured
by assigning the identification ID from 2951 to 3000.
ID identification table for devices connected on the
horizontal bus
In the first column the identification IDs that can be assigned to the
69RS.1 expansion interfaces are numbered.
In the second column there are the windows of the identification
IDs referring to the electronic units (corresponding to the identifi-
cation ID of the 69RS.1). In the third column there are the identifi-
cation IDs that the electronic unit sends to the expansion interface
(corresponding to the identification ID of the 69RS.1). In the fourth
column there are the identification IDs of the relays (corresponding
to the identification ID of the 69RS.1).
In the fifth column there are the identification IDs of the buttons
6120 (corresponding to the identification ID of the 69RS.1). In the
sixth column there are the identification IDs of the switchboards
(corresponding to the identification ID of the 69RS.1). In the sev-
enth column there are the identification IDs of the separators (cor-
responding to the identification ID of the 69RS.1).
On the last line there are the identification IDs that can be as-
signed to the devices on the HORIZONTAL BUS (electronic units
from 1 to 36, relays from 2951 to 3000).
The instruction manual is downloadable from the
site www.vimar.com
Installation rules
Installation should be carried out by qualified personnel in
compliance with the current regulations regarding the installation of
electrical equipment in the country where the products are installed.
Conformity
EMC directive
Standards EN 60065, EN 61000-6-1 and EN 61000-6-3.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may
contain traces of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or
packaging, this means the product must not be included
with other general waste at the end of its working life. The
user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one. Products
for disposal can be consigned free of charge (without any new
purchase obligation) to retailers with a sales area of at least 400m
if they measure less than 25cm. An efficient sorted waste collection
for the environmentally friendly disposal of the used device, or its
subsequent recycling, helps avoid the potential negative effects on
the environment and people's health, and encourages the re-use
and/or recycling of the construction materials.
EN
,
2
5
Tabla de contenido
loading

Tabla de contenido