- It serves to decrease any of the values
shown in the display. Keep the key
depressed to reach the required value
faster.
- After switching the machine on, two central
standby lines are displayed indicating that
no function has been selected (vacuum,
gas or sealing). Press this key for 3 seconds
to display the number of hours of
operation.
Vacuum
This key is used to select/display the vacuum
time, from 0 to 80 seconds. The LED lights
up when the vacuum time is selected and
during the vacuuming stage.
Sealing
It selects/displays the sealing time, from 0 to
7 seconds. The LED lights up when the
sealing time is selected and during the
sealing stage.
Progressive decompression
Activates/deactivates the soft air option. The
LED lights up if the option is activated.
Cycle switch
This key has three functions depending on
whether the lid is open or closed.
Lid closed → Stop – cycle switch
Each time it is pressed the cycle is interrupted
and switches to the next stage. By pressing
the key several times the end of the cycle is
reached and the air inlet is activated.
Lid open- VAC- NORM
If you press the key, when the lid is open, the
machine starts extacting air, producing the
vacuum in external containers. Pressing the
key again restores the normal operating
mode.
With the lid open and displaying "oil" we can
reset the hours of operation of the pump. By
pressing the "stop" key for 3 seconds the
counter resets and the "oil" indicator
disappears.
In order to set the parameters, it is an
ESSENTIAL REQUIREMENT that the COVER
SHOULD BE OPEN. The parameter setting
procedure is described below, taking a
possible cycle as an example:
Vacuum: 20 s.
Sealing: 3 s.
1. Press the Vacuum key. The LED of this key
turns on. Then, press the incrementer key
till 20 is displayed, which corresponds to
the selected vacuuming time.
2. Press the Sealing key. The LED of the key
turns on. Using the Incrementer or
Decrementer key, have value 3.0 being the
duration in seconds of bag sealing,
displayed.
3. Press the Soft Air key. The built- in LED
turns on, indicating that the Soft Air
function is enabled.
4. In order to change any of the entered
values at any time, it is as simple as to
press the relevant function key and to
select the new value with the Incrementer
or Decrementer key.
5. Close the cover immediately after having
selected all the values of the cycle. The
settings are stored automatically.
On closing the cover, the working cycle starts
automatically. As the cycle is carried out, the
key built- in LEDs successively turn on,
showing the stage of the cycle in progress.
At the end of the sealing stage, air enters the
chamber and the cover opens automatically.
VAC- NORM FUNCTION
The VAC- NORM function enables creating a
vacuum in trays. To be able to use this
function, you need to purchase the VAC-
NORM kit that includes a hose and connector
to the chamber of the vacuum packing
machine.
1- Before activating the VAC- NORM function,
fit the connector and hose into the
machine suction inlet.
2- Activate the VAC- NORM function, by
pressing the STOP button with the lid of
the vacuum packer open. Now, the
machine starts extracting air.
3- Place the free end of the hose into the tray.
Now, a vacuum is created inside the tray.
A vacuum gauge shows the amount of
vacuum produced. On reaching the
desired vacuum, remove the hose from
the tray.
4- Press the STOP button again or switch the
machine off; this restores the normal
mode of operation.
Warning! It is advisable to disable the VAC-
NORM function when not in use; otherwise
the machine would be extracting air
continuously, which is harmful to the pump.
If it is not switched off manually the board
automatically disconnects the pump.
DRY OIL
After switching the machine on with the
general switch, displaying the two central
lines, and pressing the "up" key for 3 secs, the
display shows "do" Dry oil cycle ("dry- oil").
With "do" on the display and by closing the
lid, the dry oil cycle starts, which lasts 15
minutes.
During the cycle the "do" text flashes and
the time remaining (in minutes) to finish the
cycle is displayed.
With the cycle in operation, press STOP to
end it.
BAG CUTTING
The bars including bag cutting threads are
supplied as an optional kit.
To install them, the sealing bar must be
replaced by the new bar provided with the
cutting thread and one of the wires in the
sealing transformer must be changed to the
power indicated on the electric layout:
For the bag cutting operation, it is enough to
programme the suitable sealing time in the
control panel and, once the bag is sealed, it
is separated manually along the line marked
by the cutting thread.
DIRECTIONS FOR USE AND MAINTENANCE
Very important: Never pack products if they
are still hot, since the vapour generated by
them damages the vacuum pump.
- It is important to clean the interior and
edges of the chamber, as well as the locking
joint, every day.
- The outside of the machine must not be
washed under a direct water jet; instead
you can use a wet cloth and an ordinary
detergent. Never clean the cover with
alcohol, solvent or glass- cleaners since
they can affect the mechanical properties
of the material and break it. If you
appreciate a crack in the cover, stop the
machine and call the authorised technical
service for repairs; there is a risk of cover
breaking.
- In the event the power cable should get
damaged and have to be replaced, the
repair may only be done by a SAMMIC
approved assistance service.