Troubleshooting - THERMOBILE IMA 61 Manual Del Usuario

Ocultar thumbs Ver también para IMA 61:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
English
Hot
Do not touch the flue and air outlet!
Wait until the flue and the air are cooled
down before maintenance.
5.2
General
Warning
Disconnect the electric power during
maintenance!
When you store the heater for a long period:
1.
Let the heater burn for 3 minutes. This
protects the pump against corrosion.
2.
Keep the burner head free from dust and
sediment.
A dirty burner head causes bad combustion
that makes soot and carbon and damage to
the burner chamber.
3.
Close the valve for the fuel supply.
4.
Disconnect the electric power.
5.3
Adjustment air inlet and electrodes
(Fig. 9)
A
Distance nozzle - electrode
B
Distance nozzle - swivel disc
C
Height nozzle centre - electrode
D
Distance between electrodes
5.4
Electrodes (Fig. 10)
Check the electrodes:
1.
Remove the rain cover (A) of the heater
(Fig. 5).
2.
Remove the cover of the burner.
3.
Remove the plug from the connector (I).
4.
Loosen the screws (A).
5.
Remove the burner base plate (B).
6.
Clean and readjust the electrodes (F).
The electrodes must be free of dirt, grease,
fuel, etc.
If the points of the electrodes are burned too
much, and adjustment is impossible, replace
the electrodes.
7.
Loosen the screw (D).
8.
Readjust the electrodes.
Install the burner head in the reverse order.
Replace the electrodes:
1.
Do the points 1 to 6 of "Check the
electrodes".
2.
Remove the electrode cables (C).
3.
Replace the electrodes.
4.
Adjust the electrodes (Fig. 9).
Install the burner head in the reverse order.
20
40.019.003 - rev 08 - 2016
20
40.019.003 - rev. 06 - 2011
ENGLISH
5.5
Nozzle (Fig. 10)
Warning
Do not touch the filter of the nozzle. This
will damage the nozzle.
Check the nozzle:
1.
Remove the rain cover (A) of the heater
(Fig. 5).
2.
Remove the cover of the burner.
3.
Remove the connector (I).
4.
Loosen the screws (A).
5.
Remove the burner base plate (B).
6.
Check the nozzle (H).
If the nozzle is black because of soot or coke,
replace the nozzle.
Install the burner head in the reverse order.
Replace the nozzle:
1.
Do the points 1 to 6 of "Check the nozzle".
2.
Remove the electrode cables (C).
3.
Loosen the screw (E) half a turn.
4.
Remove the complete holder with swivel disc
and ignition pins.
5.
Replace the nozzle. Use the correct type!
6.
Install the complete holder with swivel disc
and ignition pins.
7.
Readjust the electrodes (Fig. 9).
Install the burner head in the reverse order.
5.6
Photocell (Fig. 11)
Check the photocell:
1.
Remove the rain cover (A) of the heater
(Fig. 5).
2.
Remove the cover of the burner.
3.
Pull the photocell (A) out of the base plate
(B).
4.
Clean the photocell if the glass is black.
If the glass is cracked, the photocell must be
replaced by the dealer.
Install the photocell in the reverse order.
5.7
Air pressure at swivel disc (Fig. 12)
1.
Remove the rain cover (A) of the heater
(Fig. 5).
2.
Remove the cover of the burner.
3.
Adjust screw (A) of the air inlet according to
the table. Use a hexagonal key.
Higher scale value (B): reduced pressure
behind the swivel disc: upper output range.
Lower scale value (B): increased pressure
behind the swivel disc: lower performance
range.
4.
Place the covers again.
IMA
IMA
ENGLISH
/i
Heater
Air pressure at swivel disc
IMA 61
3.0 ± 0.5
IMA 111
1.0 ± 0.5
IMA 150
3.5 ± 0.5
IMA 200
3.5 ± 0.5
5.8
Air flow at the fan of the burner (Fig.
13)
1.
Remove the rain cover (A) of the heater
(Fig. 5).
2.
Loosen the lock nut (A).
3.
Adjust screw (B) of the air inlet according to
the table. Use a hexagonal key.
Higher scale value: increased air volume.
Lower scale value: reduced air volume.
4.
Fasten the lock nut.
5.
Place the cover again.
/i
Heater
Air quantity setting
IMA 61
3.5 ± 0.5
IMA 111
2.0 ± 0.5
IMA 150
4.5 ± 0.5
IMA 200
3.0 ± 0.5
5.9
V-belt replacement (Fig. 14)
1.
Remove the cover (A).
2.
Lower the motor by using the adjusting nuts
(C).
3.
Remove the old V-belts (B).
6.1
Table troubleshooting
/i
Fault
Cause
The heater does
1
The heater has no electric power. Check the power connection.
not start.
2
The burner relay is in failure: the
light burns.
3
The burner relay has a fault.
4
The room thermostat setting is
incorrect.
5
The room thermostat is defective. Replace the thermostat.
6
No cap is present on the
thermostat connection.
7
The fuel pump is blocked.
8
The thermostat stopped the
heater (maximum thermostat).
9
The sensor of the thermostat is
defective. The display shows the
"Sbr" error code.
IMA
40.019.003 - rev 08 - 2016
I
M
A
4
0
0 .
1
9
/i
Heater
V-belt tension
Pressure
Displacement
IMA 111
1.4 kg
2.5 mm
1 x 230 V
IMA 111
2 kg
7.8 mm
3 x 400 V
IMA 150
2.6 kg
9.0 mm
1 x 230 V
IMA 150
2.6 kg
9.0 mm
3 x 400 V
IMA 200
2.6 kg
9.0 mm
1 x 230 V
IMA 200
2.6 kg
9.0 mm
3 x 400 V
Fit new V-belts in the reverse order.
Caution
Tighten the V-belts according to the
table.
6

TROUBLESHOOTING

Make sure that the electricity is
connected and the fuel tank is full
before you troubleshoot.
Warning
Disconnect the electric power during
repair!
Solution
Push the reset button of the
burner relay.
Replace the burner relay.
Correct the adjustment.
Fit the cap if a room thermostat is
not used.
Replace the fuel pump.
Check (and correct) the airflow.
Reset the thermostat.
Replace the sensor.
0 .
0
3
-
e r
. v
0
6
-
2
0
1 1
English
Action
User
User
Dealer
User
Dealer
User
Dealer
User