INSTRUCTIONS FOR POSITIONING THE UNIT
- The geared motor unit has been assembled in the factory to be fitted to the
LEFT SIDE of the gate (internal view). To install the motor to the RIGHT of
the gate set parameter number 9 in the electronic programmer.
MANUAL OPENING
Manual release is to be carried out with the motor stopped. To release the gate
use the manual release key supplied with the unit. The key should be kept in
an easily accessible place.
To release the unit
1. Rotate the lock protection disk on the release knob,
insert the key and rotate it half a turn anticlockwise.
The knob is now free and can be released.
2. Rotate the knob through 90° anticlockwise. The
gears are now released and the gate can be moved
manually.
To relock the unit
1. Rotate the handle anticlockwise and move it back to the blocked
position.
2. Rearm the gears:
- electrically by giving an opening or closing command;
- by slightly moving the gate
3. Rotate the key clockwise and relock the handle.
Once the system has been reset store the key in a safe place
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Attention! Never use the manual release mechanism while the gate
is in operation. If you release the gate and then give a movement
command the following symbol will appear on the display .
9
A
ELECTRONIC PROGRAMMER
Electronic programmer for a dc motor with an incorporated radio receiver card,
which allows the memorisation of 300 user codes (see "remote control" page
18). The "rolling code" type decoder uses 433.92 MHz. series transmitters.
The motor rotation speed is electronically controlled, starting slowly and increas-
ing in speed; the speed is reduced as it nears the travel limit so as to enable a
controlled smooth stop.
Programming is carried out using two buttons and allows you to configure the
system the current sensor and the entire gate travel distance.
The logic carries out position control using an encoder.
SCALA: 1:2
The intervention of the anticrush/antidrag sensor during the closing and opening
Drawing number :
Description :
Prodotti Technocity
DI0243
Sblocco carter
Product Code :
SL1524
stages causes a brief (10 cm) travel direction inversion then a block.
Draft :
P.J.Heath
Date :
07-02-2002
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
ELECTRICAL CONNECTION
Open the "Standard wiring diagram". To make it easier to follow the instructions
the diagram has been placed on the inside of the last page of this manual.
ELECTRONIC CARD DESCRIPTION (fig. 10 page 44)
B1
Signal buzzer "via radio" mode
CN1
Secondary Faston connection 24Vac logic power supply
CN2
Secondary Faston connection motor circuit power supply
V2:0Vac, V3:20Vac, V4:30Vac
CN3
Battery Faston connection
CN4
Motor Faston connection
D1
Seven segment display
E1
Encoder connection
F1
15A blade fuse
(1)
F2
4A blade fuse
(1)
F3
15A blade fuse
(1)
7
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
SCALA: 1:2
Description :
Drawing number :
DI0242
Access to the electronic card
Sblocco motore
Product Code :
SL1524
Draft :
P.J.Heath
Date :
07-02-2002
Attention! Before opening the cover make sure that
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
the power has been switched off at the mains.
To access the motor loosen the two screws "A"
positioned on either end of the cover as indicated
in figure 9.
(motor power protection)
(24V circuit protection)
(motor power protection during battery operation)
F4
4A blade fuse
J1
Radio channel selection
J2
Enable transmitter memorisation via radio
J3
Manual operation selection
L1
LED power on
L2
LED battery connection error
L3
LED undercharged battery error
L4
LED manual operation mode
L5
LED transmitter code programming
L6
LED blocking button activated
L7
LED stop photocell activated
L8
LED inverting photocells activated
M1
Memory module
P1
Programming button (PROG)
P2
Selection button (SEL)
P3
Transmitter code cancellation button (DEL)
All rights reserved. Unauthorised copying or use of the information contain
P4
Transmitter code memorization button (MEMO)
R1
Radio frequency module, 433 MHz for S449 transmitters
T1
Battery charger volt adjustment trimmer
LP
Flashing warning lights
8
LS
Indicator light
FTC-RX Photocell receiver
FTC-TX Photocell transmitter
PS
Safety buffer pressure switch
TB
Blocking button
ANS
External antenna 433 MHz
• Before connecting the appliance make sure that the voltage and
frequency rated on the data plate conform to those of the mains
supply.
• An all pole trip switch with at least 3mm between the contacts must
be installed between the unit and the mains supply.
• Don't use cables with aluminium conductors; don't solder the ends
of cables which are to be inserted into the binding posts; use cables
marked T min 85°C and resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the
wire and the insulating sheath are tightly fastened (a plastic jubilee
clip is sufficient).
Mains power supply connection
• Connect the control and security device wires.
• Run the mains power supply through the cable clamp located on the bottom
Prodotti Technocity
right of the main circuit board and to the
separate 3-way terminal board:
- connect the neutral to binding post N
- connect the earth to binding post
- connect the live to binding post
Terminal board connection
1
Common for all inputs and outputs.
24Vdc output, powering external loads
2
3
Common for all inputs and outputs.
24Vdc controlled output, powering external loads
4
5
Common for all inputs and outputs.
LS 24Vdc 3W output for an indicator light.
6
7
Common for all inputs and outputs.
LP 24Vdc output for warning lights.
8
25W intermittent activation (50%), 12,5W continuous activation
9-10 Common for all inputs and outputs.
11
FTC_I (NC contact) Safety and control devices in input (photocells invert
the travel direction when an obstruction is detected). The opening of this
contact will provoke a travel direction inversion during closure due to the
cutting in of the safety device.
12
FTC_S (NC contact) Safety and control devices in input (stop photoelectric
cells/safety buffer).
13
Common for all inputs and outputs.
14
TB (NC contact) Stop button input (The opening of this contact interrupts
the cycle until a new movement command is given).
15
TC (NO contact) Closing button input
16
TA (NO contact) Opening button input
17
Mass for radio receiver antenna
18
Pole for radio receiver antenna (if an external antenna is fitted use a coaxial
type cable RG58 with an impedance of 50Ω)
All unused NC contacts must be jumped and their relative security device test
deactivated(FTC_S,FTC_I).IfyouwanttoactivatetheFTC_S,FTC_Itestboththe
transmission and receiver parts of the security devices must be connected to the
binding post marked "CTRL 24Vdc". If the test is active there will be a 1 second
delay between the command transmission and movement of the gate/door.
Note
: These are automotive type blade fuses
(1)
Note
: The total of the 2 external device outputs must not exceed 10W.
(2)
Scala 1:1
14
(24V circuit protection during battery operation)
(1)
N
L
L
.
(2)
.
(2)