ELECTRONIC PROGRAMMER

Electronic programmer for a dc motor with an incorporated radio receiver
card, which allows the memorisation of 300 user codes (see "remote control"
page 20).
The 'rolling code' type decoder uses 433 MHz series transmitters.
The travel speed is electronically controlled, starting slowly and increasing
in speed; the speed is reduced as it nears the travel limit so as to enable
a controlled smooth stop (if deceleration hasn't been excluded during pro-
gramming). Programming is carried out using two buttons and allows you
to configure the system, set the length of the deceleration stage and set the
work and pause times. The intervention of the anticrush/antidrag sensor
during the closing and opening stages causes travel direction inversion (if
automatic reclosing has been activated). If activated towards the end of the
movement (almost closed) it will act as a travel limit.
Soft stop
In each blocking manoeuvre (even the one preceding travel direction
inversion) the stopping of the motor is carried with a slight trip stage (0.4
seconds) in which the gate leaf keeps moving due to inertia and not by
the motor (which is no longer receiving power). Once this brief stage has
ended the gate leaf will be definitely blocked. Consequently when you are
positioning the catch which will activated the travel limit you must bear in
mind that there will be a slight delay between the instant in which the travel
limit activates and when the gate leaf blocks.
ELECTRICAL CONNECTION
• Open the "Standard wiring diagram". To make it easier to follow the
instructions the diagram has been placed on the inside of the last page
of this manual.
ELECTRONIC CARD DESCRIPTION (fig.12)
b1
Signal buzzer "via radio" mode
CN1 Secondary Faston connection 24 Vac logic card power supply
CN2 Secondary Faston connection motor circuit power supply
V0:0 Vac, V1:22 Vac, V2:30 Vac
CN3 Battery Faston connection
D1
Seven segment display
F1
1,6 A delayed action fuse (230 V power supply protection)
F2
1 A rapid action fuse (24 V circuit protection)
F3
10 A rapid action fuse (motor power supply protection)
J1
Enable transmitter memorisation via radio
J2
Radio channel selection
L1
LED power on
L2
LED transmitter code programming
L3
LED manual operation mode
L4
LED inverting photocells activated
L5
LED opening travel limit
L6
LED closing travel limit
L7
LED blocking button activated
L8
LED stop photocell activated
M1
Memory module
P1
Programming button (PROG)
P2
Selection button (SEL)
P3
Transmitter code memorization button (MEMO)
P4
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
LP
Flashing warning lights
LS
Indicator light
FCA
Opening travel limit
FCC
Closing travel limit
FTC-Rx Photocell receiver
FTC-Tx
Photocell transmitter
PS
Safety buffer pressure switch
SEL
Selector switch
Tb
Blocking button
ANS400 External antenna
Before connecting the appliance make sure that the voltage and
frequency rated on the data plate conform to those of the mains
supply.
A multiple pole trip switch with a least 3 mm between the contacts
must be installed between the unit and the mains supply.
• Connect the control and security device wires.
• Connect the power supply cable to the device.
• Do not use cables with aluminium conductors; do not solder the ends of
cables which are to be inserted into the binding posts; use cables which
are marked T min 85°C and are resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the wire and
the insulating sheath are tightly fastened (a plastic jubilee clip is sufficient).
If possible use the supplied cable clamp.
Terminal board connection
1-2
Common for all inputs and outputs.
3
24 Vac
(1)
in output, powering external devices
4-5
Common for all inputs and outputs
6
LP 24 Vac 10 W
(1)
in output warning lights.
7-8
Second radio channel output:
max. load ac/dc 60 VA/24 W
-
max. voltage 30 Vac/dc
-
TD (contact normally open) dynamic button input "Open-Close"
9
10
Tb (contact N.C.) Blocking button input (The opening of this contact
interrupts the cycle until a new movement command is given).
11
Common for all inputs and outputs.
12
FCC (normally closed contact) closing travel limit switch.
13
FCA (normally closed contact) opening travel limit switch.
14
FTCI (normally closed contact) Safety and control devices in input
(photocells invert the travel direction when an obstruction is detected).
The opening of this contact will provoke travel direction inversion
during closure due to the cutting in of the safety device.
FTCS (normally closed contact) Safety and control devices in input
15
(stop photoelectric cells). The opening of this contact will block all
movement, until the obstruction has been removed, due to the safety
device cutting in, the gate will then continue moving until it reaches
a travel limit (only in the automatic mode).
16
TC (contact normally open) Closing button in input
17
TA (contact normally open) Opening button in input
18
TAL (contact normally open) limited opening button
Indicator light 24 Vac 3 W
19-20
230 Vac in output powering the toroidal transformer
21-22
Power supply 230 Vac
23-24
25-26
230 Vac 40 W Courtesy light in output
27
Programmer earth wire
28
Motor earth output
29
Outer conductor for radio receiver antenna
30
Inner conductor for radio receiver antenna (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50Ω).
Note
If the device is fitted with batteries the output voltage during blackouts
(1)
will be in direct current. It follows therefore that you must make sure that the
external devices connected to these outputs can work of direct current.
ALL UNUSED NC CONTACTS MUST bE JUMPED
Switch on the power and make sure that the red indicator LEDS are in the
following condition:
- L1
Power on LED
- L2
Transmitter code programming LED
- L3
Manual operation mode LED
- L4
Safety LED for the inverting photoelectric cells "FTCI"
- L5
Opening direction travel limit LED "FCA"
- L6
Closing direction travel limit LED "FCC"
- L7
Safety LED for the blocking button "Tb"
- L8
Safety LED for the stop photoelectric cells "FTCS"
*The LEDs are "ON" if the relative security device is inactive (depends on the
position of the gate).
Check that the activation of the safety devices switches the corresponding
LEDS off.
If the red power on LED doesn't light up check the condition of the fuses and
the power cable connection between binding posts "23" and "24" (fig. 12).
If one or more of the safety LEDS do not light up check the contacts of the
relative safety devices and check that the unused safety device contacts have
been bridged.
16
on
off
off
on
on*
on*
on
on
Tabla de contenido
loading

Este manual también es adecuado para:

Sl402409

Tabla de contenido