PROGRAMMING PROCEDURE (limited opening setting and encoder programming)
CONTINUED FROM PAGE 16
PRESSING THE "PROG" BUTTON MOVES YOU TO STAGE
"B" LIMITED OPENING SETTINGS. THE DEFAULT VALUE
IS 2 METRES. THE LIMITED OPENING SETTINGS RANGE
FROM A MINIMUM OF 2 METRES TO A MAXIMUM OF 7
METRES.
Limited
opening
2 metres
PRESS
SEL
Limited
opening
3 metres
PRESS
SEL
Limited
opening
4 metres
PRESS
SEL
Limited
opening
5 metres
PRESS
SEL
Limited
opening
6 metres
PRESS
SEL
Limited
opening
7 metres
PRESS
SEL
WAIT FOR ABOUT 20 SECONDS
WITHOUT PRESSING ANY BUTTONS:
THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND
WILL QUIT PROGRAMMING.
IMPORTANT: IF YOU PROGRAM A
LIMITED OPENING GREATER THAN THE
TOTAL AVAILABLE OPENING SPACE, THE
LIMITED OPENING WILL BE THE SAME AS
THE OPENING TRAVEL DISTANCE.
PRESSING THE "PROG" BUTTON MOVES YOU TO STAGE "C" ENCODER PROGRAMMING. THIS IS
THE DISTANCE THE GATE/DOOR WILL TRAVEL FOR BOTH THE OPENING AND CLOSING STRETCHES.
THE LETTER "
SECONDS. DURING THIS TIME PERIOD
THE PROGRAMMER CARRIES OUT A TEST
OF THE SAFETY DEVICES. (ONLY IF THE
TEST HAS BEEN ACTIVATED, SEE
PROGRAMMING SETUP STEPS 7/8)
THE TEST HAS FAILED. IN THIS CASE YOU
MUST REPLACE THE DEFECTIVE SECURITY
DEVICES OR BRIDGE THEIR NC CONTACTS
AND DEACTIVATE THE RELATIVE TEST (SEE
PROGRAMMING SETUP STEPS 7/8) BY
PRESSING THE "PROG" BUTTON AND
RETURNING TO STAGE "A".
ONCE YOU HAVE PRESSED THE "PROG"
BUTTON THE PAUSE TIME WILL START
INDICATED BY THE MIDDLE SEGMENT
FLASHING ON THE DISPLAY
ATTENTION! IF THE GATE MOVES IN THE
OPENING DIRECTION IT MEANS THAT
PARAMETER NINE IS NOT CORRECT AND YOU
WILL HAVE TO PRESS "PROG" TO CANCEL THE
PROGRAMMING PROCEDURE AND START AGAIN
FROM STAGE "A" .
WHEN THE GATE IS COMPLETELY CLOSED IT WILL INVERT THE TRAVEL DIRECTION FOR A FEW
CENTIMETRES AND THEN CLOSE AGAIN IN ORDER TO CHECK THE POSITION OF THE MECHANICAL
TRAVEL LIMIT. AT THIS POINT THE GATE WILL OPEN SLOWLY UNTIL IT REACHES THE OTHER TRAVEL
LIMIT; AFTER IT HAS MOVED ABOUT HALF A METRE THE GATE WILL STOP FOR A FEW SECONDS TO
CHECK THE INERTIA AND THEN MOVE AGAIN UNTIL IT REACHES THE OPENING TRAVEL LIMIT. AT THIS
POINT IT WILL INVERT THE TRAVEL DIRECTION FOR A FEW CENTIMETRES AND THEN MOVE BACK TO
THE OPENING TRAVEL LIMIT TO CHECK THE POSITION OF THE MECHANICAL TRAVEL LIMIT.
AFTER CARRYING OUT THIS MOVEMENT THE GATE WILL CLOSE AGAIN AND WILL STOP MOVING FOR
A FEW SECONDS TO MEASURE ITS INERTIA; ONCE IT HAS ARRIVED AT THE COMPLETELY CLOSED
POSITION (4–5 CM FROM THE TRAVEL LIMIT) THE CONTROL LOGIC WILL CARRY OUT A COMPLETE
OPENING AND CLOSING CYCLE IN ORDER TO SET THE CURRENT SENSOR.
PRESS
PROG
THE OPERATION WAS NOT SUCCESSFUL.
YOU WILL HAVE TO REPEAT THE
PROGRAMMING CYCLE.
Automatic repositioning
PRESS
If the programmer blocks due to an encoder count error
PROG
, the warning lights and indicator light will flash simultaneously for 2 seconds and will
then switch off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after pre-flashing
1...20 sec.
for 10 seconds) automatically move the gate, slowly, to the completely closed position
(2 times as in the programming procedure) in order to recover the correct position. At this
point the programmer will function normally.
To carry out automatic repositioning without waiting for 3 minutes you may send a (TA,
TC or TD via radio) command to the programmer.
No commands will be accepted during repositioning but the security devices will cut in
and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another 3 minutes, press the
"PROG" button.
t
" APPEARS FOR ABOUT 2
17
1...2 sec.
THE TEST WAS SUCCESSFUL (OR IT WAS
DEACTIVATED). THE DISPLAY SWITCHES OFF
AND AT THIS POINT YOU ARE READY TO
START THE PAUSE COUNT
PRESS PROG
PRESS PROG
THE PAUSE TIME COUNT WILL END AND THE
GATE WILL CLOSE SLOWLY UNTIL IT REACHES
THE COMPLETELY CLOSED POSITION.
WHEN THE GATE/DOOR REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER WILL SAVE THE PARAMETERS
AND WILL QUIT PROGRAMMING.
or after a programmer reset
Tabla de contenido
loading

Este manual también es adecuado para:

Sl15241524

Tabla de contenido