Replacing Edge Brush; Replacing The Led Light; Stuffing Or Blockage; Important - Oreck HEPA Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Replacing Edge Brush

WARNING: Unplug cord from electrical outlet before servicing.
22
Turn the power head over. With baseplate facing up, remove the screw located in the center of each edge brush.
Remove both edge brushes and replace with new ones. Replace both screws and tighten.

Replacing the LED Light

The light assembly should be replaced by an Oreck authorized service center whenever it fails to light during operation.

Stuffing or Blockage

IMPORTANT: On plush and new carpets, stuffing may occur inside the intake tube and the lower tube assembly. This is due to excessive fuzz
and loose cuttings in the carpet. Stuffing could occur for the first few cleanings until all the loose material is removed. Due to the high efficiency
of the cleaner, many older carpets will cause stuffing when the cleaner is first used on them. If your vacuum cleaner does not pick up properly, or
makes unusual noise and the outer bag does not fluff up or balloon open, follow these steps:
WARNING: Unplug cord from electrical outlet before servicing.
Check for blockage at the mouth of the intake opening. If there is blockage, remove it with long-nose pliers,
23
a screwdriver or coat hanger. If you can not reach the blockage, remove baseplate. Remove the base plate by removing 5 screws
(see "Replacing Brushroll").
24
If the blockage is not at the base, remove lower tube. Unhook bag spring, releasing bottom of bag.
Twist lower collar counterclockwise to slide up. Pull tube out of base. Check for blockage. If blockage is in the tube, remove with a coat hanger.
25
26
If tube is not blocked, look into fan housing. Remove debris with long-nose pliers, a screwdriver or coat hanger.
To reassemble, check O-ring on tube, and replace if damaged. Replace tube by first lining up slot at base of tube with tab inside fan housing.
27
Insert tube and push down until the tube is seated. Make sure O-ring is in place against fan housing opening. Replace and tighten collar until
28
collar locking tabs are locked in place. Reattach bag spring.
Many times blockage occurs due to a full HEPA Inner bag causing dirt to back down the air flow system. When that
29
happens, the blockage will be at the top of the system, starting in the area where the HEPA Inner bag connects to the connector assembly.
Note: If the above actions do not correct the problem, contact an Oreck authorized service center or call the
customer service center. US: 1-800-989-3535 Canada: 1-888-676-7325
23
7
E
N
24
25
G
L
I
S
H
25
26
27
28
29
22
Tabla de contenido
loading

Tabla de contenido