INSTALLATION
Commissioning
10.2.7 Temperature limit
CAUTION Burns
When operating with preheated water, the set tempera-
ture limit may be ineffective.
f In such cases, limit the temperature with an up-
f
stream central thermostatic valve.
You can adjust the temperature limit inside the appliance cover.
1
1 Max. 43 °C
2 Max. 60 °C
f Connect the cable to position 1 (43 °C).
f
The temperature can be set to between 30 °C and 43 °C.
10.3 Completing the installation
f Open the shut-off valve in the twin connector or the cold
f
water inlet line.
11. Commissioning
WARNING Electrocution
Commissioning must only be carried out by a qualified
contractor in accordance with safety regulations.
www.stiebel-eltron.com
11.1 Initial start-up
2
f Open and close all connected draw-off valves several times,
f
until all air has been purged from the pipework and the
appliance.
f Carry out a tightness check.
f
f Activate the safety pressure limiter by firmly pressing the reset
f
button (the appliance is delivered with the safety pressure
limiter deactivated).
f Plug the temperature selector cable plug into the PCB.
f
f Fit the appliance cover, ensuring it clicks into place. Check that
f
the appliance cover is seated correctly.
f Switch the mains power ON.
f
f Check the function of the appliance.
f
3
L3'
4
L2'
1
L1'
2
PEY 18/21/24 |