Samsung NX58M6650W Serie Manual De Instalación página 17

Ocultar thumbs Ver también para NX58M6650W Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Wiring diagram is located on the back of the range. (Inside of the cover back
wire)
This range is equipped with an electronic ignition system that will not operate
if plugged into an outlet that is not properly polarized.
Gas models
All gas models are equipped with a power cord with an equipment-grounding
conductor and a grounding plug.
A 120-Volt, 60-Hz, AC, approved electrical service with 20-amp circuit breaker
or time-delay fuse is required for all U.S. and Canadian models.
Check for ¾-in (1.9-cm) UL-listed strain relief where the power cord comes out
of the range cabinet.
Do not reuse a power supply cord from an old range or other appliance.
The power cord electric supply wiring must be retained at the range cabinet
with a suitable UL-listed strain relief.
A time-delay fuse or circuit breaker is also recommended.
Ensure proper
ground and
firm connection
before use.
The plug must be firmly plugged into a three-prong outlet that is properly
installed and grounded in accordance with all local codes and ordinances. In
the event of a malfunction or breakdown, grounding will decrease the risk of
electrical shock by providing a path for the electric current.
Do not use a damaged power plug or loose wall outlet.
Do not use an extension cord or adapter with this appliance.
NX5000M_NX58M6650WS_AA_DG68-00992A-00_EN+MES+CFR.indb 17
All ranges must be grounded for
personal safety.
All gas models have a power cord with
an equipment-grounding conductor and
a grounding plug.
Do not, under any circumstances, cut, modify, remove, or otherwise defeat the
grounding (third) prong from the power cord. If the plug and the outlet do not
match or you have any doubt, have a qualified electrician install the proper
outlet.
The customer should have the wall receptacle and circuit checked by a
qualified electrician to make sure the receptacle is properly grounded.
Ground Fault Circuit Interrupters (GFCIs) are not required or recommended for
gas range receptacles.
NEVER connect ground wire to plastic plumbing lines, gas lines, or water
pipes.
CAUTION
Failure to follow these instructions can result in death, fire, or electrical shock.
English 17
7/4/2017 4:07:09 PM
Tabla de contenido
loading

Este manual también es adecuado para:

Nx58m6630s serie

Tabla de contenido