Safety Messages for Wiring

When installing and operating flame-proof electrical equipment,
the relevant national regulations for installation and operation (e.g.,
EN60079-14, IEC Wiring Regulations and NEC/CEC) must be
observed.
To maintain the flame-proof integrity of the enclosure, DO NOT
damage the LED lens cover or threads while disassembling or
reassembling unit.
To avoid electrical shock hazards, do not connect wires when
power is applied. Failure to observe this warning may lead to
serious injury or death.
Painting and surface finishes, other than those applied by Federal
Signal Corporation, are not permitted.
Cable termination should be in accordance with specifications
applying to the application. Federal Signal recommends that all
cables and cores should be fully identified.
Ensure that only the correct equipment-certified glands are used and
that the assembly is shrouded and correctly earthed. Gland entries
are M20-1.5 6H with an option for the M25 entry on the end of the
increased safety box models. See Table 3 on page 29 for choosing
correct cable entry devices for Equipment in Potentially Explosive
Atmospheres.
Because of space limitations, ensure the cable cores within the
unit are not too slack.
In all countries, the wiring must comply with all national and local
codes and standards.
Ensure that all nuts, bolts, and fixings are secure.
Model G-LED Global Series LED Beacon
Installation and Maintenance Instructions
13