ClEariNG all rEmotE CoNtrols
Press the PROG button on the motorisation control unit for more than 7 seconds. The indicator light flashes to indicate that all
remote controls have been cleared.
diaGNostiCs
The auto-diagnostic LEDS, located on the control unit terminal, control the
operation of the motor and its additional devices.
DL2
START - lights up on the START command
DL3
STOP - goes out on the STOP command
DL4
PHOT - goes out if the photoelectric cells are not aligned or if they are
obstructed
DL5
SWO - goes out on the opening end limit command
DL6
SWC - goes out on the closing end limit command
tEChNiCal sPECifiCatioNs
Power supply
Motor power supply
Motor revolutions
Power consumption
Maximum consumed current
Capacitor
Thermal protection
Insulation category
Reduction ratio
Revolutions at output
Pinion
Gate speed
Maximum weight of the gate
Maximum torque
Lubrication
Manual manoeuvres
Number of cycles/day
Obstacle detection
Control unit
Operating temperature
Index protection rating
Weight
Dimensions
Accessories power supply
Automatic closure time
Operating time
Pedestrian opening time
Reversal pause
Flashing orange light connection
Fuses
Built in radio receiver
Number of storable remote controls
RTS remote control frequency
Aerial resistance
10
motor
230 V 50Hz
230 V AC
1400 rpm
290 W
1.5 A (230 V) - 3 A (110 V)
10 μF (230 V) - 40 μF (110 V)
110°C
F
1/30
48 rpm
4 mm module (14 teeth)
8.5 m/min
500 kg
20 Nm
Permanent grease
Mechanical release with handle
100
Friction clutch
Integrated
-15 °C to +60 °C
IP24
15 kg
see "General motor size" pg. 3
ElECtroNiCs
24 V (0.2 A maximum absorbed)
between 0 and 90 seconds
between 0 and 120 seconds
7 seconds (fixed)
1 second approximately
230 V maximum 15 W
250 V T 0.62 A and T 1 A
RTS
36
433.42 Mhz
50 Ohm (RG58)
Copyright © 2008 Somfy SAS. All rights reserved.