2. Press the Enter key. The display will read
either "1DRAIN" or "2DRAIN." The
normal prompt for most applications is
"1DRAIN." "2DRAIN" is used only for
special applications. Consult factory for
full details. To choose the alternate feature,
press key 0.
Note: Enabling the second drain via the
Auxiliary 2 output precludes control of the
recirculation pump and is not necessary for the
Premium Wet Clean Module.
3. Press the Enter key. The display will read
either "ADV" or "NO ADV." The prompt
"NO ADV" will disable the Advance key
in the RUN mode, thereby preventing the
operator from advancing the computer
through steps of the cycle before they are
complete; also, it will not be possible to
advance to any step before starting a cycle
if "NO ADV" is selected. To choose the
alternate feature, press key 0.
4. Press the Enter key. The display will read
either "MANUAL" or "NO MAN." If
"MANUAL" is displayed, the manual
mode will be enabled during normal
operation. If "NO MAN" is displayed, the
manual mode will be disabled when a
cycle is run, even if the Manual operation
key sequence is entered. To choose the
alternate feature, press key 0.
5. Press the Enter key. The display will
read either "WET CL" or "NO WCL."
To choose the alternate feature, press
key 0. If "WET CL" is displayed,
wet clean functions are enabled. If
"NO WCL" is displayed, wet clean
functions are disabled.
F232089
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
6. Press the Enter key. The display will read
"S BAL" (short balance timing sequence)
or "L BAL" (long balance timing
sequence. The "L BAL" setting should be
chosen on all UW models of Design 6 or
greater.
On all UW models of Design 5 or lower,
the "S BAL" should be chosen if the
machine capacity is 60 lbs. or less, and the
"L BAL" setting should be chosen if the
machine capacity is greater than 60 lbs.
However, if the machine is a UW50PVT,
UW55PVT or UW60PVT, the "L BAL"
option should be chosen.
This setting will have no effect if the
machine is not equipped with an AC
Inverter drive balance detection system.
Note: The design series can be found on the
serial decal of the machine. Example:
UW60PVQU50001 or UW60PVQU60001.
The inverter drive balance-timing
sequence, if active, will occur during a
drain step. This prevents the machine from
reaching a high speed when a poorly
balanced load is sensed. The short timing
sequence ("S BAL") and the long timing
("L BAL") are as follows:
• WE-6 enters drain step (displays "D1,"
"Da" or "Db") with drain(s) initially
closed.
• Machine runs at regular wash speed
forward (not 1/2 wash speed) for a total
of 15 seconds if "S BAL" or for a total
of 20 seconds if "L BAL."
• Machine runs at distribution speed for a
total of 15 seconds if "S BAL" or for 20
seconds if "L BAL."
• Drain(s) open.
35