Sw it ch in g ON a n d OFF: Switching ON - the waterbath may be turned ON (I) at the mains
switch located a t t h e r ea r . When ON (I) the switch is illuminated and unit performs a self test
where all segments of the 3 digit LED display and indictors illuminate.
Switching OFF: the waterbath may be turned OFF(O) at the mains switch located at the rear.
All current temperature and time values remain in memory. The switch will automatically
click o f f when the waterbath is u n p lu gged . When the waterbath is subsequently plugged
in, the unit must be s w it ch ed o n using the m a in s s w it ch a t t h e r ea r.

Keyboard Description

FUNCTION
- Press once "SP1" is displayed.
- Press twice "t" is displayed, timer setting.
DOWN ARROW
- Used to decrease a value. Hold continously to scroll.
- When pressed for more than 1.5 seconds, "SP1" is displayed.
UP ARROW
- Used to increase a value. Hold continously to scroll.
RUN
- When pressed for more than 1.5 seconds will activate/deactivate timer
function.
- Used to turn off buzzer.

LED Indicators

HEATING INDICATOR
When LED is illuminated waterbath is being heated.
TIMER INDICATOR
- Continous illumination indicates timer is set.
- Flashing illumination indicates timer is running back/counting down.
SET TEMPERATURE INDICATOR
- Continous illumination indicates set point is shown on display.
The Sammic waterbath features a low liquid level protection system. If the liq-
uid level drops below the predetermined point the heating will cease and dis-
" FIL L "
play will flash between "FILL" and actual bath temperature. To clear message
and resume heating refill waterbath.