The microswitches on RA terminals, set the opening stop by default.
However, to activate the opening slowdown, do the following:
a) - Set dip switches 5 and 6 to ON (and dip switches 1, 2, 3, 4
to OFF); ;
b) - press CH2: the red PROG led will start to blink;
c) - when the led stays on (after about 5 seconds) the procedure
is complete;
d) - set to the dip switches back to OFF (or to the previous
position, which depends on the functions selection, see
paragraph 7, page 12).
N.B.: to return to default, follow the same procedure while pressing
CH1.
a)
6.3 - POWER SUPPLY TO ACCESSORIES
Terminals for powering the following accessories:
- 24V a.c. (normally alternated power)
- 24V a.c. (continuous power) when the emergency batteries
are in operation.
Overall power allowed: 34W
Power supply
230V (a.c.) 50/60 Hz
6.4 - SIGNALLING AND LIGHTING DEVICES
Open gate indicator-light
(socket rating: 24V - 3W max.).
- Turns on when the gate is ajar
or open. It turns off when the gate
is closed.
(Also see Chapt. 6.5)
b)
c)
CH2 = Opening
slowdown
d)
Signal Flasher
(socket rating: 24V - 25W max.)
- Flashes during opening and
closing phases
default
CH1 = Opening
stop