Adjustment
$ Gen-lock adjustment
Phase adjustments must be performed with the camera or
the RCU (RCB) when external synchronizing signals are
supplied to the system in cases where multiple cameras are
used or peripheral devices are connected.
U Horizontal phase control
Observe the waveform of the external synchronizing input
signal (black burst signal) and video output signal on a
two-channel oscilloscope. Then match the horizontal phase
of both signals by adjusting them with the cameras or RCU's
horizontal phase control.
External gen-lock input signal
(black burst output of special effect
generator)
Video signal
Adjust the horizontal phase
[ADJUSTMENT by CAMERA]
1. Press the NO/BAR switch for over 5 seconds to display
the colour bar.
2. Select [G/L Adjustment] on the main menu, then select [H
Phase] on the submenu.
3. Adjust the horizontal phase with the YES/ABC and
NO/BAR switch.
[ADJUSTMENT with RCU (RCB, hybrid control panel)]
Use the horizontal phase control.
Horizontal phase
control
- 25 (E) -
NO/BAR switch
YES/ABC switch
Subcarrier phase