WIRING DIAGRAM
Videokit type 68IA/R (black/white), type 68IA/RC (colour)
- It is possible to reverse the polarity of the two connecting wires bet-
ween power supply unit and monitor and between power supply unit
and entrance panel.
- The cable recommended for connecting the kit is type 732H (2x1mm²)
and/or 732I ( 2x1mm²). If the cable used is not one of those indicated
above, the following guarantees do NOT apply.
- The installation is guaranteed up to a maximum distance of 150 me-
tres. Distance intended as the straight-line distance between the 2
devices furthest apart (e.g. the furthest entrance panel and the fur-
thest monitor). The total length of extended cable must not exceed
500 metres. These maximum distances apply to both B/W and co-
lour installations.
- Electric locks connected to the entrance panels must have a maxi-
mum input current of 1 A at a voltage of 12 Vdc.
- Electrical disturbances or discharges may affect the operation of the
devices. Therefore we recommend laying the cables inside separate
tubes.
B2
B1
A1 + A2 + B1 + B2 = Max 150 m
A1 + A2 + C1 + C2 = Max 150 m
Art. 68TC/K, 68TU/K
C2
C1
A1
A2
9/32