ELECTRODES - DEFLECTOR SETTING
After having installed the nozzle, check the correct position of the electrodes and deflector according to the
following levels. It is adviseable to check levels after every intervention on head.
ECO 5N - 5RN - 5LN
PUMP PRESSURE ADJUSTMENT
The pump pressure is pre-set during production at 12 bar.
For controlling pressure use an oil bathed manometer.
The pressure can be adjusted from 11 to 14 bar for ECO 5N - 5LN and from 7 to 14 bar for ECO 5RN.
SUNTEC
INDEX
1
Intake
Return
2
3
Nozzle
Pressure Adjustment
4
COBUSTION HEAD ADJUSTMENT
Head adjustment is made by the screw 1, as for indications of index 2.
2÷3
2÷3
DANFOSS
3
6÷6,5
DELTA
Prex. bar
4
1009DIS387
m H O
2
2
1
19
3