Allmatic XTILUS Serie Manual Del Usuario página 17

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7. INSTALLATION
Before fastening the brackets provided, establish the A and B (Fig. 3) coordinates using the data given in Table 1. These data
are valid if the gearmotor is at maximum extension minus one centimetre of the available stroke (C D ) when the gate is closed
to obtain maximum working efficiency. To anchor the piston, use the fastening brackets provided.
Note: data B in the table, with reference to the single values A, are to be considered as values recommended.
Establish coordinates A + B that are to be used: the sum of coordinates establishes the stroke used C U .
Note: the stroke used (C U ) of the gearmotor must never be equal or greater than the available stroke (C D ) = 400mm.
TABLE 1
ANGLE
A
90
110
90°
110
90
130
160
110°
160
A+B=C U (stroke used) / C D = (maximum available stroke) = 400 mm
Fig. 3
NO!
SI!
Fig. 4
6-1624846
rev. 16
B
C
195
120
180
120
150
90
210
90
130
120
140
120
150
120
A
NO!
ATTENTION! in opening position, the angle should not be
negative. The installation is not correct. See examples at page 6
13/11/2018
D
E
75
76
60
76
60
76
120
76
10
76
20
76
30
76
SI!
Figure
L max
C u
pag. 6
760
285
760
290
760
260
760
300
760
260
760
300
760
310
1
2
3
4
5
-
-
17 / 52
Tabla de contenido
loading

Este manual también es adecuado para:

Xtilus 24v12007408120074891200741112007406

Tabla de contenido